Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles.

Abstract

A modified implanted drop foot stimulator that allows cyclic modulation of the stimulation pulse-width during gait has been developed. Stimulation was on two channels of a four-channel 12 polar cuff electrode. The stimulator allowed modulation of stimulation pulse-width, between 0 and 255 micros, on both channels throughout the swing and stance phases of gait. Stimulation was applied between 17 and 40 Hz. The clinician can specify an infinite range of stimulation profiles on a desktop computer, using a user-friendly LabVIEW interface. The desktop program generated a stimulation profile table of 100 values, which was then downloaded to the drop foot stimulator. As each phase of gait imposed different biomechanical demands on the ankle dorsiflexor muscles, different stimulation intensities were desirable, throughout gait, to match these demands. Moreover, as the gait of each person with hemiplegia is unique, the biomechanical demands imposed throughout the gait cycle for each user of a drop foot stimulator are unique. This stimulator architecture allowed the clinician to, specify stimulation intensities individually, at each phase of the gait cycle for each drop foot stimulator user. The stimulator was evaluated on a male hemiplegic subject. It was used to increase the stimulation pulse-width by 150% at 5% of gait cycle prior to heel strike. The system performed well, with the ankle angle at heel strike increasing by 5 degrees owing to this increased pulse-width.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T O'Halloran, M Haugland, G M Lyons, T Sinkjaer. 2003. Modified implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width profiles.. https://doi.org/10.1007/bf02349978

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling biological motor control for human locomotion with functional electrical stimulation.

This paper develops a novel control system for functional electrical stimulation (FES) locomotion, which aims to generate normal locomotion for paraplegics via FES. It explores the possibility of applying ideas from biology to engineering. The neural control mechanism of the biological motor system, the central pattern generator, has been adopted in the control system design. Some artificial control techniques such as neural network control, fuzzy logic, control and impedance control are incorporated to refine the control performance. Several types of sensory feedback are integrated to endow this control system with an adaptive ability. A musculoskeletal model with 7 segments and 18 muscles is constructed for the simulation study. Satisfactory simulation results are achieved under this FES control system, which indicates a promising technique for the potential application of FES locomotion in future.

Electric Stimulation Therapy↗

Complications and troubleshooting of two-stage sacral neuromodulation therapy: a single-institution experience.

OBJECTIVES: With the increasing use of sacral neuromodulation therapy, urologists are faced with postimplantation challenges. The purpose of this study was to identify these events and their causes and management in our large single-institution experience. METHODS: From July 2002 to September 2004, all patients who underwent sacral neuromodulation therapy for refractory bladder conditions were identified. Their medical records were retrospectively evaluated for history, operative intervention, and programming visits. Events after implantation of the implantable pulse generator (IPG) unit were noted. The evaluation, troubleshooting, management, and resolution of events at the last follow-up visit were extracted. RESULTS: A total of 214 patients underwent sacral neuromodulation therapy at our institution. The mean patient age was 53.5 +/- 15.4 years. Of the 214 patients, 161 underwent IPG implantation during a mean follow-up period of 16 months (range 5 to 30). The second-stage explantation and revision rate was 10.5% and 16.1%, respectively. The indications for explantation were infection (8 of 17) and failure to maintain a response (9 of 17). Revisions were done for decreases in response with abnormal (12 of 26) or normal (5 of 26) impedance measurements, IPG site discomfort (4 of 26), draining sinus at the IPG site (4 of 26), and lead migration (1 of 26). Equalization of impedance measurements was the most commonly observed impedance abnormality. These were managed by drying fluid from the connection in 4 patients and lead change in the rest. CONCLUSIONS: After IPG implantation, a decline in response may occur. Although some were explanted, most were revised, with most of the revisions functional on follow-up. Familiarity with impedance evaluation and development of algorithms for postimplant management are essential for troubleshooting and maintenance of the device.

Electric Stimulation Therapy↗