Multiple-image radiography.

Abstract

Conventional radiography produces a single image of an object by measuring the attenuation of an x-ray beam passing through it. When imaging weakly absorbing tissues, x-ray attenuation may be a suboptimal signature of disease-related information. In this paper we describe a new phase-sensitive imaging method, called multiple-image radiography (MIR), which is an improvement on a prior technique called diffraction-enhanced imaging (DEI). This paper elaborates on our initial presentation of the idea in Wernick et al (2002 Proc. Int. Symp. Biomed. Imaging pp 129-32). MIR simultaneously produces several images from a set of measurements made with a single x-ray beam. Specifically, MIR yields three images depicting separately the effects of refraction, ultra-small-angle scatter and attenuation by the object. All three images have good contrast, in part because they are virtually immune from degradation due to scatter at higher angles. MIR also yields a very comprehensive object description, consisting of the angular intensity spectrum of a transmitted x-ray beam at every image pixel, within a narrow angular range. Our experiments are based on data acquired using a synchrotron light source; however, in preparation for more practical implementations using conventional x-ray sources, we develop and evaluate algorithms designed for Poisson noise, which is characteristic of photon-limited imaging. The results suggest that MIR is capable of operating at low photon count levels, therefore the method shows promise for use with conventional x-ray sources. The results also show that, in addition to producing new types of object descriptions, MIR produces substantially more accurate images than its predecessor, DEI. MIR results are shown in the form of planar images of a phantom and a biological specimen. A preliminary demonstration of the use of MIR for computed tomography is also presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Miles N Wernick, Oliver Wirjadi, Dean Chapman, Zhong Zhong, Nikolas P Galatsanos, Yongyi Yang, Jovan G Brankov, Oral Oltulu, Mark A Anastasio, Carol Muehleman. 2003-12-07. Multiple-image radiography.. https://doi.org/10.1088/0031-9155%2F48%2F23%2F006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple non invasive computerized method for the assessment of bone repair within osteoconductive porous bioceramic grafts.

Single energy X-ray imaging, due to its low cost and flexibility, is one of the most used and common technique to assess bone state and bone remodeling over time. Standardized X-ray images are needed to compare sets of radiographs for semi-quantitative analyses of tissue remodeling. However, useful mathematical modeling for the analysis of high level radiographic images are not easily available. In order to propose a useful evaluation tool to a wide clinical scenario, we present an innovative calibration algorithm for a semi-quantitative analysis of non-standardized digitized X-ray images. For calibration on a unique standardization scale, three time invariant regions (ROI) of radiographs were selected and analyzed. The accuracy of the normalization method for X-ray films was successfully validated by using an aluminum step wedge for routine X-ray exposures as tool to standardize serial radiographs (Pearson correlation test: R(2) = 0.96). This method was applied to investigate the progression of the new bone deposition within ceramic scaffolds used as osteoconductive substitute in large bone defects taking advantage of a large animal model. This innovative image-processing algorithm allowed the identification and semi-quantification of the bone matrix deposited within the implant. The osteo-integration at the bone-implant interface was also investigated. A progressively increasing bone tissue deposition within the porous bioceramic implant and a progressive osteo-integration was observed during the 12 months of the trial.

Absorptiometry, Photon↗

Combined LIBD and XAFS investigation of the formation and structure of Zr(IV) colloids.

The solubility of Zr(OH)4(am)--in other words hydrated Zr(IV) oxyhydroxide--is determined by means of coulometric titration (CT), and colloids are detected by laser-induced breakdown when the solubility limit is exceeded. Our results at pH 3-8 demonstrate that the solubility of Zr(OH)4(am) is several orders of magnitude higher than reported classical solubility data for acidic solutions, determined from undersaturation with a less soluble microcrystalline Zr(IV) oxide precipitate. Analysis of extended X-ray absorption fine structure (EXAFS) data shows that the microcrystalline colloids in a 0.1 mol l(-1) Zr aqueous solution at pH 0.2 contain tetrameric units, similar to those present in the structure of ZrOCl2.8H2O. Characterization of the CT solutions by means of EXAFS shows that oligomeric species form as the solubility limit is approached. The current lack of data on equilibrium constants for polynuclear hydroxide complexes prohibits the use of a realistic speciation model to describe the solubility of pH-dependent Zr(OH)4(am). However, the solubility curve is obtained using the mononuclear hydrolysis constants estimated in the present paper, along with the solubility constant (log K'sp=-49.9+/-0.5 in 0.5 mol l(-1) NaCl; log K degrees(sp)=-53.1+/-0.5 at I=0).

Absorptiometry, Photon↗

Three-dimensional modeling of EXAFS spectral mixtures by combining Monte Carlo simulations and target transformation factor analysis.

We have developed a new method for the three-dimensional modeling of extended X-ray absorption fine structure (EXAFS) spectra which enables the extraction of the local structure of aqueous metal complexes from spectral mixtures of several components. The new method combines two techniques: Monte Carlo simulation and target transformation factor analysis (TFA). Monte Carlo simulation is used to create random arrangements between the X-ray absorbing metal ion and the ligand atoms, and to calculate the theoretical EXAFS spectrum of each arrangement. The theoretical EXAFS spectrum is then introduced as test spectrum in the TFA procedure, to test whether or not the test spectrum is likely to be a component of the spectral mixtures. This coupled procedure is repeated until the error in the test spectrum is minimized. The new method can thus be used to isolate and refine the structure of complexes from spectral mixtures and to determine their relative concentrations, solely on the basis of an estimate of a ligand structure. The performance of the proposed method is validated using uranium Liii-edge EXAFS spectra of binary mixtures of two uranium(VI) 3,4-dihydroxybenzoic acid complexes.

Absorptiometry, Photon↗