PubMed Health⌕ Search

PubMed · 14719760

Total-etch versus self-etch adhesive: effect on postoperative sensitivity.

Abstract

BACKGROUND: Self-etching adhesives are believed to prevent postoperative sensitivity when used under posterior resin-based composite restorations. The authors tested a twofold hypothesis: a self-etch, or SE, adhesive would result in less postoperative sensitivity than a total-etch, or TE, adhesive; an SE adhesive would result in poorer enamel marginal integrity than a TE adhesive. METHODS: Patients were selected on the basis of requiring Class I and II restorations in molars and premolars. The authors placed 30 restorations with the SE material (Clearfil SE Bond, Kuraray America, New York) and 36 restorations with Prime & Bond NT (Dentsply Caulk, Milford, Del.), which uses 34 percent phosphoric acid to etch enamel and dentin simultaneously. Preparations were of standard design, with all margins in enamel without beveling. Upon rubber dam isolation, the authors conditioned the enamel and dentin walls with the self-etching primer (for Clearfil SE Bond) or etched with the proprietary 34 percent phosphoric acid (for Prime & Bond NT), followed by application of the corresponding dentin adhesive. Teeth were restored with the proprietary hybrid resin-based composite indicated for posterior restorations: Clearfil AP-X for Clearfil SE Bond or Esthet-X Micro Matrix Restorative for Prime & Bond NT. The restored teeth were evaluated preoperatively and at two weeks, eight weeks and six months postoperatively for sensitivity to cold (ice), air and masticatory forces, as well as for marginal discoloration. RESULTS: Analysis of variance revealed no statistically significant differences in postoperative sensitivity between the SE and TE materials at any recall time. Marginal discoloration was rated as "absent" for all restorations at six months. Only one tooth displayed sensitivity to occlusal forces at six months. CONCLUSION: The SE adhesive did not differ from the TE adhesive in regard to sensitivity and marginal discoloration. CLINICAL IMPLICATIONS: Postoperative sensitivity may depend on the restorative technique rather than on the type of dentin adhesive used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jorge Perdigão, Saulo Geraldeli, James S Hodges. 2003. Total-etch versus self-etch adhesive: effect on postoperative sensitivity.. https://doi.org/10.14219/jada.archive.2003.0109

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of hydration variability on hybrid layer properties of a self-etching versus an acid-etching system.

The hypothesis tested in this study was that the self-etching system (Clearfil SE Bond, CSE) is less sensitive to surface moisture variability than the system that uses a separate acid-etching step (Single Bond, SB). Eighteen dentin specimens were bonded to composite using CSE or SB. Three different surface moisture conditions per bonding type (overwet, w; dry, d; and visibly moist, n [normal]) were applied prior to bonding dentin to composite. One cross section of each sample was analyzed with lines of nanoindentations crossing perpendicular to the bonding interface. An additional set of bonded samples was fixed and cross sectioned before the hybrid layer thickness was measured in scanning electron microscopy. The nanoindentations revealed significant differences in indentation modulus (E(i)) and hardness (H) for the hybrid layer comparing SBn, E(i) = 2.7(+/-1.6); H = 0.24(+/-0.1) GPa with SBd, E(i) = 0.9(+/-0.7); H = 0.9(+/-0.05) GPa, respectively, while CSE showed no differences among the groups. A significantly greater demineralized zone below the hybrid layer was found for SBd. The hybrid layer was wider for both CSEd and SBd. In conclusion the hypothesis was verified; CSE exhibited no significant changes of hybrid layer properties (E(i), H) at different hydration conditions, while SB had significant differences, especially after air-drying.

Acid Etching, Dental↗

A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives.

This study provided morphological evidence that discrepancies between the depth of demineralisation and the depth of resin infiltration can occur in some mild self-etch adhesives. Sound dentine specimens derived from extracted human third molars were bonded with 5 one-step and 5 two-step self-etch adhesives. One millimeter thick slabs containing the resin-dentine interfaces were immersed in 50 wt% aqueous ammoniacal silver nitrate and processed for TEM examination. A zone of partially etched but uninfiltrated dentine was identified beneath the hybrid layers in the milder versions of both one-step and two-step self-etch adhesives. This zone was characterised by the occurrence of silver deposits along the interfibrillar spaces of mineralised collagen fibrils. The silver infiltrated interfibrillar spaces were clearly identified from the one-step self-etch adhesives Xeno III, iBond, Brush&Bond and the experimental adhesive, and were thinner and only occasionally observed in the two-step self-etch adhesives Clearfil SE Bond and Clearfil Protect Bond. The more aggressive one-step and two-step adhesives that exhibit more abrupt transitions from completely demineralised to mineralised dentin were devoid of these silver-infiltrated interfibrillar spaces beneath the hybrid layers. Incomplete resin infiltration observed in some self-etch adhesives may be caused by the reduced etching potential of the acidic monomers toward the base of hybrid layers, or the presence of acidic but non-polymerisable hydrolytic adhesive components, creating potential sites for the degradation of the bonded created by these self-etch adhesives.

Acid Etching, Dental↗

[Ultrastructural study of sclerotic dentin in non-carious cervical lesions disposed by a total-etching dentin adhesive].

OBJECTIVE: To examine the ultrastructure of resin-infiltrated sclerotic dentine following the application of a three-step total-etching dentin adhesive. METHODS: Naturally-occurring, non-carious cervical lesions on extracted premolars were bonded using a total-etching dentin adhesive-Scotchbond Multi-purpose. Artificially prepared wedge-shaped lesions were also made in sound premolars and restored using the same adhesive as control. The morphological change of the dentin surface conditioned with the etchant, and the hybrid zone and resin tags in the dentin-resin interface were studied by SEM. RESULTS: Most dentinal tubules were obliterated by rod-like sclerotic casts in the non-carious cervical lesion, and could not be dissolved by Scotchbond Multi-purpose etchant. Both the hybrid zone and resin tags were observed in sclerotic dentin after restoration, although the resin tags were fewer and in lack of communications, the length of resin tags and the thickness of the hybrid zone were almost similar to those of the sound dentin. CONCLUSION: Bonding to sclerotic dentin is different from sound dentin, and may be compromised by the fewer resin tags and communications.

Acid Etching, Dental↗