PubMed Health⌕ Search

PubMed · 14763798

Simple strategy for the optimization of solid-phase extraction procedures through the use of solid-liquid distribution coefficients application to the determination of aliphatic lactones in wine.

Abstract

A practical strategy for the optimization of solid-phase extraction (SPE) systems is presented. Critical SPE volumes (sample loaded, rinsing and elution solvent) are calculated from solid-liquid extraction coefficients and from basic bed parameters determined in simple experiments, using the Lövkist Jonsson model and other expressions derived from the general theory of chromatography. The agreement between calculated and measured volumes is satisfactory, which makes it possible to consider different sorbents and rinsing and elution solvents in the SPE optimization with a relatively low experimental effort. The strategy has been successfully applied to the optimization of a SPE method directed to the selective extraction of aliphatic lactones from wine. Six different reversed-phase sorbents were studied and the one showing maximum extraction selectivity was selected. Wine (50 ml) is extracted in a 200 mg cartridge filled with Bond Elut-ENV resins. Interferences are removed with 20 ml of methanol-water (40:60) with 1% NaHCO3. Elution is carried out with 1.8 ml of dichloromethane. The extract is concentrated to 0.15 ml and analyzed by GC-ion trap MS. Eight odor-active aliphatic gamma and delta lactones (with 8-12 C atoms) from wine are recovered (R > 75%) in an extract free from wine major volatiles. Detection limits are in the 40-300 ng/l range, well below the odor detection threshold of these compounds. Linearity (r2 > 0.996) and precision (average R.S.D. 3.5%) are satisfactory in all cases. The levels in wine of some of these lactones (gamma-octa, undeca and dodecalactones) are reported by first time and results demonstrate that can be present at concentrations above or close to their corresponding odor thresholds.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vicente Ferreira, Idoia Jarauta, Lina Ortega, Juan Cacho. 2004-02-06. Simple strategy for the optimization of solid-phase extraction procedures through the use of solid-liquid distribution coefficients application to the determination of aliphatic lactones in wine.. https://doi.org/10.1016/j.chroma.2003.10.086

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of phenolic metabolites of polycyclic aromatic hydrocarbons in human urine as their pentafluorobenzyl ether derivatives using liquid chromatography-tandem mass spectrometry.

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental contaminants, and a number of them are carcinogenic. One approach for measuring exposure to them is to determine the concentrations of metabolites in urine. The pyrene metabolite 1-hydroxypyrene has been used as a biomarker for exposure in numerous studies. However, determination of exposure to several PAHs may be advantageous, since the relative amounts may vary depending upon the exposure source. We developed a liquid chromatography-tandem mass spectrometry method for the determination of phenolic metabolites of naphthalene, fluorene, phenanthrene, and pyrene in human urine. Following enzymatic cleavage of the glucuronide and sulfate conjugates, the phenolic metabolites are extracted from urine and converted to pentafluorobenzyl ethers. These derivatives greatly enhance the sensitivity of detection by atmospheric pressure chemical ionization in the negative ion mode. Lower limits of quantitation range from 0.01 to 0.5 ng/mL. Stable isotope-labeled internal standards were synthesized or obtained commercially. Data on urinary excretion of several PAH metabolites in urine of smokers and nonsmokers are presented.

Chromatography, Liquid↗

MicroSPE-nanoLC-ESI-MS/MS using 10-microm-i.d. silica-based monolithic columns for proteomics.

Silica-based monolithic capillary columns (25 cm x 10 microm i.d.) with integrated nanoESI emitters have been developed to provide high-quality and robust microSPE-nanoLC-ESI-MS analyses. The integrated nanoESI emitter adds no dead volume to the LC separation, allowing stable electrospray operation at flow rates of approximately 10 nL/min. In an initial application with a linear ion trap MS, we identified 5510 unique peptides that covered 1443 distinct Shewanella oneidensis proteins from a 300-ng tryptic digest sample in a single 4-h LC-MS/MS analysis. The use of an integrated monolithic ESI emitter provided enhanced resistance to clogging and provided good run-to-run reproducibility.

Chromatography, Liquid↗

Method validation for the analysis of 169 pesticides in soya grain, without clean up, by liquid chromatography-tandem mass spectrometry using positive and negative electrospray ionization.

Part of a comprehensive study on the comparison of different extraction methods, GC-MS(/MS) and LC-MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC-MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate. After centrifugation, aliquots of the extract were evaporated and reconstituted in 1.0 mL of methanol, before direct injection of the final extract (corresponding with 0.05 g soya mL(-1)) into the LC-MS/MS system. Linearity, r(2) of calibration curves, instrument limit of detection/quantitation (LOD/LOQ) and matrix effect were evaluated, based on seven concentrations measured in 6-fold. Good linearity (at least r(2)> or =0.99) of the calibration curves was obtained over the range from 0.1 or 0.25 to 10.0 ng mL(-1), corresponding with pesticide concentrations in soya bean extract of 2 or 5-200 microg kg(-1). Instrument LOD values generally were 0.1 or 0.25 ng mL(-1). Matrix effects were negligible for approximately 90% of the pesticides. The accuracy, precision and method LOQ were determined via recovery experiments, spiking soya at 10, 50, 100 microg kg(-1), six replicates per level. In both ESI modes, method LOQ values were mostly 10 or 50 microg kg(-1) and more than 70% of pesticides analysed by each mode met the acceptability criteria of recovery (70-120%) and RSD (< or =20%), at one or more of the three levels studied. A fast, easy and efficient method with acceptable performance was achieved for a difficult matrix as soya, without cleanup.

Chromatography, Liquid↗