PubMed Health⌕ Search

PubMed · 14840404

A balanced non-cephalic reference electrode.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W A STEPHENSON, F A GIBBS. 1951. A balanced non-cephalic reference electrode.. https://doi.org/10.1016/0013-4694(51)90017-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Concentric needle electrodes are superior to perineal surface-patch electrodes for electromyographic documentation of urethral sphincter relaxation during voiding.

OBJECTIVE: To compare interpretations of electromyographic (EMG) recordings from perineal surface patch electrodes (PSPEs) to those from urethral concentric needle electrodes (CNEs) during voiding. PATIENTS AND METHODS: Consenting women underwent urodynamic testing with a 30 G, 3.8 cm CNE at the 12 o'clock position in the striated urethral sphincter muscle, and with PSPEs placed at the 2 and 10 o'clock positions around the anus. Pressure-flow studies were conducted with simultaneous input from both EMG electrodes. Representative, de-identified paper copies of EMG signals were assembled by chronology and electrode type. Six examiners unaware of the patient details were asked to determine if the tracings were interpretable and whether there was quiescence of the urethral sphincter motor unit during voiding. The agreement between the interpretations of each tracing was assessed using McNemar and kappa statistics. RESULTS: Twenty-two women undergoing urodynamic testing for incontinence (16), voiding dysfunction (two) or urinary retention (four) participated in this study. CNE tracings were consistently more interpretable than PSPE tracings (mean 89% vs 67%). When tracings were interpretable, a significantly higher percentage of CNE EMG tracings (mean 79%) had urethral sphincter motor unit quiescence than PSPE EMG tracings (mean 28%). The kappa values for agreement among the reviewers' interpretations were highly variable and none were statistically significant. Reviewers unanimously agreed on only 12 of the 44 tracings, and 11 of these showed quiescence when using a CNE. CONCLUSIONS: CNEs are more often interpretable than PSPEs for determining motor unit quiescence during voiding. CNE EMG appears to have greater clinical utility for central reading than PSPEs.

Electrodes↗

The role of electrode impedance and electrode geometry in the design of microelectrode systems.

Microelectromechanical systems (MEMS) employing spatially and/or temporally nonuniform electric fields have been extensively employed to control the motion of suspended particles or fluid flow. Design and control of microelectromechanical processes require accurate calculations of the electric field distribution under varying electrolyte conditions. Polarization of electrodes under the application of an oscillating voltage difference produces dynamic electrical double layers. The capacitive nature of the double layers significantly inhibits the penetration of the electric field through the double layer and into the surrounding bulk electrolyte at low frequencies. This paper quantitatively discusses the effect of electrode impedance on the electric field distribution as a function of field frequency, electrolyte composition, and electrode zeta potential in microelectrode systems. The design principles for the electrode geometry and configuration are also discussed in terms of their effects on the electric field magnitude and nonuniformity.

Electrodes↗

Construction and evaluation of PVC and sol-gel sensor membranes based on Mn(III)TPP-Cl. Application to valproate determination in pharmaceutical preparations.

The construction and general performance of new valproate-selective electrodes based on manganese(III) tetraphenylporphyrin [Mn(III)TPP-Cl], as an ionophore, are presented. The ionophore was incorporated into PVC and ceramic membranes (sol-gel) based on methyltriethoxysilane. The influence of membrane composition and pH and the effect of lipophilic cationic and anionic additives in PVC membranes were investigated concerning their influence on the slope, response time, selectivity and lifetime of the electrodes. The PVC membrane without additive and the sol-gel membrane presented slopes and practical limits of detection of -60.8 mV dec(-1) and 5x10(-6) mol l(-1) and -60.3 mV dec(-1) and 1x10(-4) mol l(-1), respectively. The sol-gel membranes displayed higher selectivity for valproate when compared with PVC membranes. These two types of electrodes were coupled to a sequential-injection analysis (SIA) system for the direct determination of valproate in pharmaceutical formulations. The association of Mn(III)TPP-Cl with the sol-gel support inserted in a SIA system provided potentiometric sensors with an analytical range of 1x10(-3)-5x10(-2) mol l(-1), with a sample rate of 55 samples per hour and a sample and carrier consumption of 140 and 2,500 microl per determination, respectively.

Electrodes↗