PubMed Health⌕ Search

PubMed · 15031440

Name those quantities.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel J Strom. 2004. Name those quantities.. https://doi.org/10.1093/rpd%2Fnch021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of deciduous molars in EPR dose reconstruction.

In the present study naturally loose deciduous molars were investigated. The feasibility of separating enamel from small size molars was analysed. EPR spectrum parameters of whole molars and separated enamel only were evaluated before and after laboratory irradiation. The Electron paramagnetic resonance (EPR) signal amplitudes of CO (2) (-) and native signals were determined by spectrum deconvolution, as a function of radiation dose in the range 0.1-10 Gy. A detection threshold of absorbed dose from deciduous molars of 198 and 21 mGy is estimated for massive (that contained both enamel and dentine) and grainy samples (that contained enamel only), respectively. The elimination of the organic material from the massive deciduous samples reduced the mean bias dose for the native signal from 90+/-18 to 34+/-13 mGy. A decay of the background signal within 2 weeks after irradiation was found, while the dosimetric signal was stable before and after the irradiation process. The presented results suggest deciduous teeth to be suitable for retrospective dose assessment. To get reasonable dose estimates, however, any organic material must be eliminated, and the measurements should be performed 2 weeks after the chemical and mechanical preparation and the irradiation process are done.

Body Burden↗

Physical phantom of typical Korean male for radiation protection purpose.

Dose distribution within a human body can be measured using physical anthropomorphic phantoms. In an effort to establish reference Korean physical model, the first Korean physical phantom of average Korean adult male was constructed using computed tomography (CT) images of a healthy volunteer. The body dimension of the subject was close to that of average Korean male. The source images were obtained using fusion positron emission tomography machine at Radiation Health Research Institute in Korea, and ported into rapid prototyping process. The physical phantom was composed of three tissue-equivalent materials: epoxy resin, urethane foam and polyurethane representing bone, lungs and soft tissues, respectively. The densities of the tissue-equivalent materials were close to those recommended by the International Commission on Radiation Units and measurements. To facilitate dose mapping, the phantom was sliced into 2 cm sections. Hole grids for thermoluminescence (TL) dosemeter chips were drilled. To verify the appropriateness of the physical phantom, organ doses of selected organs were measured for reference photon beam, and compared with those computed by tomographic model constructed from the same CT images. Absorbed doses converted from TL relative response showed good agreement within 7% with those calculated.

Body Burden↗

Performance of a whole-body counter with five high-purity germanium detectors.

A germanium (Ge) detector system has been installed in a whole-body counting facility at NIRS (Japan). The system employs five detectors that have relative efficiencies of more than 80%. A basic performance of the Ge detectors was tested and compared with that of the former NaI(Tl) detector system. Although the Ge detector system has advantages of improved radionuclide identification capability and MDA values, it also has disadvantages of high operation costs and demanding maintenance such as supply of liquid nitrogen.

Body Burden↗