Absolute TCD4+ counting by a minimalist dual-platform flow cytometric method.

Abstract

UNLABELLED: The aim of this work was to compare the performance of an absolute TCD4+ counting method based on total WBC gating versus the standard lymphocyte (Ly) gating method, in order to develop a flow cytometric (FCM) minimalist strategy for TCD4+ enumeration. METHOD: 132 routine peripheral blood samples, mainly from HIV infected patients, were labelled with CD3-FITC/CD4-PE/CD45-PECy5 and analyzed by two gating methods: a) standard method based on Ly immunological gating (CD45++SSClow), followed by the determination of CD3+CD4+ percentage and absolute number (# calculation using Ly # from hematological analyser (HA); b) total WBC immunological gate on biparametric scatter CD45/CD4, followed by CD4++SSClow percentage determination and absolute number calculation using WBC absolute number from hematological counter without using the WBC differential. Moreover on 63 samples Ly # based on Ly % from FCM and WBC counting from HA was compared with Ly # from HA. RESULTS: The TCD4+/microL ranged from 3 to 3277 and the statistical analysis results showed: a) linear regression: r2 = 0.9847; b) Bland & Altman analysis: difference mean = -56.22; agreement range = +95.68 / -208.12; c) the mean of result difference/mean value*100 between two methods was -9.06%; d) comparison between regression line and the boundaries for acceptable residual values based on regressed confidence limits found by A. Kunkl et al showed regression line within boundaries near the upper limits. The Ly/microL count ranged from 635 to 8752. The statistical analysis results showed: a) linear regression: r2 = 0.9764; b) Bland & Altman analysis: difference mean = -362.93; agreement range = +134.51 / -860.37; c) the mean of result difference/mean value*100 between two methods was -16.12%. CONCLUSIONS: Our results suggest a fair agreement between the two gating methods, but the one based on total WBC gate gives TCD4+/microL counts systematically higher than the standard method. This finding can be attributed to a systematic lower estimation of Ly% by HA.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Chianese, E Nebuloni, M De Paschale, A Gatti, M Mena. Absolute TCD4+ counting by a minimalist dual-platform flow cytometric method.. https://pubmed.ncbi.nlm.nih.gov/15065767/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

ZrO₂@C-based colorimetric/photothermal dual-mode immunosensor coupled with a novel monoclonal antibody for quantification of Aspergillus ochraceus biomass.

Aspergillus ochraceus contaminates agricultural products and produces nephrotoxic, carcinogenic ochratoxin A (OTA), posing severe food safety hazards. A dual-signal lateral flow immunochromatographic assay (dLFIA) based on ZrO₂@C nanoprobes was established for quantitative detection of A. ochraceus biomass. A novel monoclonal antibody (mAb 4B4) was prepared as the capture antibody to immobilize A. ochraceus mycelial lysate antigen on the test line, and a rabbit polyclonal antibody (pAb G2801) as the detection antibody to modify ZrO₂@C composites (synthesized via UiO-66 pyrolysis) into 200 nm colorimetric/photothermal nanoprobes. This dLFIA achieved limits of detection of 0.164 μg/mL (colorimetric) and 0.517 μg/mL (photothermal). This efficient and reliable method allows quantitative analysis of A. ochraceus biomass, which is suitable for routine monitoring of fungal contamination in agro-food matrices.

Antibodies, Monoclonal↗

Rituximab for lymphoproliferative disease prior to haematopoietic stem cell transplantation for X-linked severe combined immunodeficiency.

Lymphoproliferative disease (LPD) is a complication of congenital and acquired immunodeficiency states. There are a number of treatment options for LPD arising after haematopoietic stem cell or solid organ transplantation including reduction of immunosuppression, targeted therapies, such as the anti-CD20 monoclonal antibody, rituximab, and EBV specific cytotoxic lymphocytes. Treatment of LPD in children with congenital immunodeficiency syndromes remains unsatisfactory and is associated with a high mortality rate. We recently managed an infant found to have polymorphic LPD concurrent with X-linked severe combined immunodeficiency (SCID). Haematopoietic stem cell transplantation (HSCT) had to be deferred because of progressive LPD. Treatment with rituximab resulted in regression of the LPD following which the patient received a 5/6 HLA matched umbilical cord blood (UCB) transplant. The patient remains well 20 months following transplantation. Rituximab treatment may have a useful role in the control of LPD associated with congenital immunodeficiency prior to HSCT.

Antibodies, Monoclonal↗

Response to rituximab in a child with neuroblastoma and opsoclonus-myoclonus.

Opsoclonus-myoclonus (OM) is a paraneoplastic syndrome of probable autoimmune origin. Despite current therapies aimed at decreasing autoantibody formation, OM is difficult to control and may impact long-term neurologic outcome. We present a case of a 19-month-old patient who initially presented with OM, neuroblastoma and a constitutional cytogenetic abnormality t(5;12)(q11.2;q15). The patient's OM was recalcitrant to conventional therapies, but showed significant improvement following treatment with rituximab.

Antibodies, Monoclonal↗