Image processing and analysis program for measurement of bone density changes in reference and follow-up standardized extraoral oblique lateral cephalometric radiographs of the mandible.

Abstract

OBJECTIVES: The aim of this study was to develop an image processing and analysis program for peri-implant bone density measurements of the mandible using extraoral radiographs, which includes a correction for the variable projection of the soft tissues of the face. METHODS: The measurement procedure is based on pairs of reference and follow-up extraoral oblique lateral cephalometric radiographs (OLCRs) of patients with endosseous implants in the anterior part of the atrophic edentulous mandible. The procedure consists of image acquisition, correction for radiographic variation using an aluminium wedge (i.e. film exposure and development) and transformation of the grey values into aluminium-equivalent values. After correction for variation in the projection of the soft tissues of the face using internal calibration fields, the actual peri-implant bone density measurements are performed. RESULTS: The soft tissue projection correction significantly reduces the variation between radiographs owing to the position of the soft tissues. CONCLUSIONS: It is concluded that the described image processing and analysis program, in combination with extraorally made OLCRs, is a valuable technique for measurement of peri-implant bone density changes of the mandible. With minor adaptations, the program can be used for other semi-edentulous patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Ruijter, J W Verhoeven, J A M van der Linden, M S Cune, M Terlou. 2003. Image processing and analysis program for measurement of bone density changes in reference and follow-up standardized extraoral oblique lateral cephalometric radiographs of the mandible.. https://doi.org/10.1259/dmfr%2F23241049

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗