PubMed Health⌕ Search

Biomedical subjects

M S Cune

Publications and source records attributed to M S Cune.

At least 19 recordsLinked to original sources

Dental implants in patients with bruxing habits.

Bruxism (teeth grinding and clenching) is generally considered a contraindication for dental implants, although the evidence for this is usually based on clinical experience only. So far, studies to the possible cause-and-effect relationship between bruxism and implant failure do not yield consistent and specific outcomes. This is partly because of the large variation in the literature in terms of both the technical aspects and the biological aspects of the study material. Although there is still no proof for the suggestion that bruxism causes an overload of dental implants and of their suprastructures, a careful approach is recommended. There are a few practical guidelines as to minimize the chance of implant failure. Besides the recommendation to reduce or eliminate bruxism itself, these guidelines concern the number and dimensions of the implants, the design of the occlusion and articulation patterns, and the protection of the final result with a hard occlusal stabilization splint (night guard).

Biomechanical Phenomena↗

[Patient satisfaction with different types of implant-retained overdentures in the edentate mandible].

The purpose of this study was to determine patient satisfaction with implant supported mandibular overdentures using magnet, bar-clip and ball-socket attachments, and to assess the relation between maximum bite force and patient satisfaction. In a crossover clinical trial, 18 edentulous patients with lower denture complaints received 2 mandibular implants and new lower and upper dentures. The lower denture initially came without any kind of attachment system, but was fitted with one of the attachment types after 3 months. The attachments were changed 3 months thereafter, in random order. A questionnaire concerning denture complaints was given at baseline (with the old denture), after 3 months of functioning with the new denture without attachments and after 3 months of functioning with each of the attachments (within-subject comparison). In addition, at the end of the experiment patients were asked to express their overall satisfaction with their dentures on a visual analogue scale (VAS). Data regarding maximum bite force were obtained from a previous study with the same population. Mandibular implant supported overdenture treatment reduced various denture complaints. The VAS score reflected patients' preference more accurately than scale-scores. Patients strongly preferred bar-clip (10 subjects) and ball-socket attachments (7 subjects) over magnet attachments (1 subject). Patients' preference could not be predicted on the basis of baseline observations. Maximum bite force was not correlated to scale- or VAS scores.

Adult↗

[Research methods in dentistry 9. Follow-up of permucosal implants in an edentate mandible using panoramic radiography].

Panoramic radiographs are frequently used for routine follow-up of mandibular implants. The objective of this study was to determine whether measurement on a panoramic radiograph of the vertical dimension of the mandible near by an implant, using the known implant length as a reference, is a reliable method. In 11 patients, 2 permucosal implants were placed in the anterior part of the edentulous mandible. During the first year after implantation, 2 panoramic radiographs and 2 sets of standardized oblique lateral cephalometric radiographs were made. Oblique lateral cephalometric radiographs are the golden standard for measuring the vertical dimension of an edentulous mandible. The length of the implants and the vertical dimension of the mandible dorsally to the implants were measured on all oblique lateral cephalometric radiographs. The measured and known implant length were used to calculate the image enlargement factor. This factor was used to calculate the real vertical dimension of the mandible. The same measurement procedures were performed on the panoramic radiographs. Using a paired t-test, the calculated values of the vertical dimensions of the mandibles found on panoramic radiographs were compared with the calculated values found on oblique lateral cephalometric radiographs. No statistically significant differences were found. It was concluded that under the described circumstances, panoramic radiographs can be used for reliable measurement of the vertical dimension of the mandible near by permucosal implants.

Cephalometry↗

[(Pain) complaints that are "not understood" after implant surgery. Diagnosis with CT/DentaScan].

Combining clinical examination and panoramic, periapical or lateral cephalometric radiographs is generally sufficient in the pre- and post-operative investigation of most implant patients. Sometimes there is a need for more information needing computer tomography (CT) as an additional diagnostic tool. The obtained CT data can be manipulated and reconstructed with software programs such as DentaScan. The resulting cross sections, that can be given in true proportions, are perpendicular to the course of the jaw. Interpretation of these processed images is much easier but not always more accurate than the original scans. Pre-operatively, CT/DentaScans can be used not only for the determination of bone quantity and quality, but also for the location of relevant anatomical structures. Post-operatively, the scans can be valuable in the diagnosis of unexplained problems that may be related to the placed implants. Three case reports illustrate the use and indication of CT/DentaScans in solving implant related maxillary pathology or neuralgic pain.

Adult↗

[A survey of implant-retained superstructure types in the edentulous mandible in The Netherlands].

Treatment of mandibular edentulousness with endosseous permucosal implants has evolved to a common treatment option during the last decades. In The Netherlands, the relative cheap prosthetic treatment of implant-supported overdentures is considered a qualitatively adequate treatment. The aim of the study described in this article was to survey the treatment of edentulous mandibles by fixed implant-supported prostheses and implant-supported overdentures, and to register the different mesostructures used. All clinics of special dental care and all larger clinics for implant dentistry in The Netherlands received a questionnaire. The data provided showed that more than 90% of patients treated with implants because of mandibular edentulousness, were provided with an overdenture. In 85% of cases a bar-clip mesostructure was used. Cost control was the most important reason to choose an overdenture above a fixed implant-supported prosthesis.

Dental Prosthesis Retention↗

[Oral pathology in a denture practice].

An 86-year-old edentulous patient visits a denturist for the provision of a new set of dentures. In the region 36/37 of the lower denture base extension is a bony like structure apparent, that does really not bother the patient. The denturist refers the patient for further diagnosis. It appeared to be a benign condition (traumatic periosteal ossification) that did not require surgical intervention. The responsibilities and capabilities of the denturist with regard to the treatment of edentulous patients are discussed in light of the current Dutch legislation.

Aged, 80 and over↗

Anterior tooth replacement with implants in grafted alveolar cleft sites: a case series.

When a residual edentulous space in the anterior region remains after surgical and orthodontic treatment of alveolar cleft patients, implant placement with or without additional grafting is a treatment option. We placed a total of 10 implants in nine consecutive alveolar cleft patients (five females, four males) with residual anterior edentulous spaces and non-restored neighbouring teeth. Patient age generally varied from 18 to 22 years. Additional (tertiary) bone grafting, implant placement after 3 months of graft consolidation and implant uncover after no less than 6 months was the favoured surgical protocol in the five most recent cases. Ample time was allowed to evaluate and guide the development of soft tissues, following second-stage surgery. For this purpose, temporary crowns were fabricated, adjusted and left in place for over 3-4 months in seven out of nine cases. No implants were lost after a mean observation period of 3.4 years and all implants function without objective (radiographic) or subjective problems. Aesthetics were considered acceptable in seven out of nine cases. Unsatisfactory aesthetic results originated from poor implant positioning or alignment in two patients who did not undergo tertiary bone grafting. We conclude that implant placement in alveolar cleft sites is a comprehensive but viable treatment option. Tertiary grafting of the site is recommended to achieve better ridge contour and bone height. This allows optimal implant placement and alignment.

Adolescent↗

Masticatory function with implant-supported overdentures.

The type of attachment that is used in implant-supported mandibular overdentures may influence the retention and stability of the prosthesis and, thus, masticatory function. In this within-subject cross-over clinical trial, we examined the hypothesis that greater retention and stability of the overdenture improve the masticatory function. Eighteen edentulous subjects received 2 oral implants, a new overdenture, and, successively, 3 different suprastructure modalities: magnet, ball, and bar-clip. Masticatory performance, masticatory efficiency, and swallowing threshold were measured. The masticatory function significantly improved after implant treatment with each of the 3 attachments. We observed small differences in masticatory function among the 3 attachment types: slightly better masticatory performance with ball and bar-clip than with magnet attachments. The number of chewing cycles until swallowing hardly decreased after implant treatment. We conclude that significantly better masticatory performance, combined with a slightly smaller number of chewing cycles after implant treatment, results in smaller food particles being swallowed.

Adult↗

[Dental implants in tooth grinders].

Bruxism (tooth grinding and clenching) is generally considered a contraindication for dental implants, although the evidence is usually based on clinical experience only. So far, studies to the possible cause-and-effect relationship between bruxism and implant failure do not yield consistent and specific outcomes. This is partly due to the large variation in the technical and the biological aspects of the investigations. Although there is still no proof that bruxism causes overload of dental implants and their suprastructures, a careful approach is recommended. Practical advices as to minimize the chance of implant failure are given. Besides the recommendation to reduce or eliminate bruxism itself, these advices concern the number and dimensions of the implants, the design of the occlusion and articulation patterns, and the use of a hard nightguard.

Bite Force↗

[An enamel disorder in two siblings].

Two sisters exhibit a similar enamel disorder. It is a hereditary developmental disorder, diagnosed as amelogenesis imperfecta. In this article the various types of amelogenesis imperfecta are discussed and the clinical consequences, genetic aspects, and basic guidelines for treatment are addressed.

Amelogenesis Imperfecta↗

Image processing and analysis program for measurement of bone density changes in reference and follow-up standardized extraoral oblique lateral cephalometric radiographs of the mandible.

OBJECTIVES: The aim of this study was to develop an image processing and analysis program for peri-implant bone density measurements of the mandible using extraoral radiographs, which includes a correction for the variable projection of the soft tissues of the face. METHODS: The measurement procedure is based on pairs of reference and follow-up extraoral oblique lateral cephalometric radiographs (OLCRs) of patients with endosseous implants in the anterior part of the atrophic edentulous mandible. The procedure consists of image acquisition, correction for radiographic variation using an aluminium wedge (i.e. film exposure and development) and transformation of the grey values into aluminium-equivalent values. After correction for variation in the projection of the soft tissues of the face using internal calibration fields, the actual peri-implant bone density measurements are performed. RESULTS: The soft tissue projection correction significantly reduces the variation between radiographs owing to the position of the soft tissues. CONCLUSIONS: It is concluded that the described image processing and analysis program, in combination with extraorally made OLCRs, is a valuable technique for measurement of peri-implant bone density changes of the mandible. With minor adaptations, the program can be used for other semi-edentulous patients.

Absorptiometry, Photon↗

[Radiographic planning and the evaluation of implant treatment].

Radiographic techniques can be used during the pre-, per- and postoperative stages of implant treatment. In the preoperative stage information is needed regarding the quantity and quality of the bone and the relevant anatomical structures of the jaw. Various radiographic techniques are available for this and all have their inherent merits and disadvantages. Occasionally there is a need of a preoperative radiograph i.e. a panoramic or periapical radiograph. In the postoperative stage radiographic techniques are used for the evaluation of bone and implants. In this stage there is a need for detailed and reproducible information regarding the cervical peri-implant bone level, the total height of the jaw and the radiographic density of the peri-implant bone. There is a limited number of radiographic techniques available in this stage.

Cephalometry↗

[Dental feats 1. An implant-supported orbital prosthesis after ablative tumor surgery].

Extraoral implants are used with increasing frequency, in order to provide retention for facial prostheses. Facial prostheses can replace lost extraoral hard and soft tissues using acrylic or silicone materials. The surgeon, maxillofacial prosthodontist and dental technician are facing particular treatment considerations and practical problems. Some of these are demonstrated and discussed in this article by means of a case-report. A patient received an orbital prosthesis which obtains its retention from implants, placed in the lateral orbital rim.

Facial Bones↗

The influence of various attachment types in mandibular implant-retained overdentures on maximum bite force and EMG.

The type of attachment that is used in oral rehabilitation by means of implant-retained mandibular overdentures may influence the retention and the stability of the denture. In this study, we examined the hypothesis that a better retention and stability of the denture improve the oral function. Eighteen edentulous subjects received 2 permucosal implants, a new denture, and, successively, 3 suprastructure modalities. Maximum bite force and electrical activity of the masseter and temporalis muscles were measured. The maximum bite force nearly doubled after treatment for each of the 3 attachments. However, the average bite force after treatment was still only two-thirds of the value obtained for dentate subjects. No large differences in maximum bite force and muscle activity were found among the 3 attachment types. Temporalis activity was significantly lower than masseter activity when subjects clenched without implant support. There was no difference in activity when subjects clenched with implant support.

Adult↗

[Onlay grafts in combination with endosseous implants in severe mandibular atrophy. A prospective radiological study].

The placement of endosseous implants in combination with iliac crest onlay grafting of the anterior mandible is one of the treatment modalities for extreme atrophy of the mandible. The remodelling of these onlay grafts was studied using standardized extraoral oblique lateral cephalometric radiographs (OLCRs). A group of 8 patients was used in this prospective study. The measurements obtained from the OLCRs indicated the existence of the following stages in the process of remodelling of the bone grafts: 1. decrease in thickness and radiographic density of the (upper) cortex of the graft, predominantly during the first half year after grafting; 2. no significant changes in the radiographic density of the upper spongeous part of the graft; 3. a mean decrease of approximately 25% in the overall thickness of the graft, particularly during the first half year; and 4. an increase in the radiographic density of the lower part of the spongeous bone in the second half year after grafting. It is concluded that the remodelling of the graft has a predictable pattern in time. Densitometric measurement using standardized OLCRs can be a useful tool to evaluate quantitative changes of bone grafts to the mandible. The treatment described can be used on very strict indications only.

Absorptiometry, Photon↗

The use of the transmandibular implant system in extreme atrophy of the mandible; a retrospective study of the results in two different hospital situations.

This retrospective study aims to investigate and compare the results obtained with the transmandibular implant (TMI) in two different hospital situations. Group I were patients treated in a teaching hospital since 1984 by a varying group of surgeons and prosthodontists with a varying degree of experience with the TMI. Group II were patients treated in 1993 and 1994 by experienced surgeons and prosthodontists in the hospital where the TMI was originally developed. In group I, a relatively high frequency of reversible (45.4%) and irreversible--i.e. implant loss--(15.2%) complications occurred. In group II, no implants were lost and reversible complications were reported in 10.8% of the patients. In general, the patients of both groups were quite satisfied with the result of the treatment. In both groups, limited bone loss around the implant posts could be observed. An increase in the height of the mandibular bone distal of the lateral posts was frequently observed, especially in group II. It is concluded that both very favourable and less favourable results can be obtained with the TMI. In this study the best results are found in a highly specialized TMI centre, where patients are treated--with only uncompromised implant-posts--by a small group of experienced surgeons and prosthodontics with accurate application of the existing guidelines.

Atrophy↗

[Clinical evaluation of the Biocomp-implant system. Results after 1,3 and 5 years in a general practice].

A population of 107 consecutive patients was treated with a new HA-coated, screw-type dental implant (n = 384 implants), the Biocomp implant. Treatment was performed in a general dental practice by one and the same dentist. The implants were utilized for various types of prosthetic constructions, sometimes in challenging conditions with respect to patient selection, jaw bone quantity and quality. A clinical and radiographical evaluation was performed after 1, 3 and 5 years. After 5 years, the chance on implant survival was 87.1% (standard error 3.4%). Implant loss occurred predominantly within the first 1.5 year after implant placement. Particularly short implants, placed in the atrofic maxilla, frequently failed. Biocomp implants that served as abutments for an overdenture in the edentulous mandible or as a single tooth replacement in the upper anterior region had an excellent prognosis.

Adolescent↗

Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and accuracy of the technique in height measurements of mandibular bone in vivo.

Various radiographic techniques are used for longitudinal studies of changes in the height of the mandible with implants. Advantages and disadvantages of panoramic radiographs, lateral cephalometric radiographs, periapical films and modern CT- and MRI-techniques are briefly discussed. In this study, the usefulness of a conventional radiographic technique for measuring the height of the mandible, i.e. oblique lateral cephalometric radiography (OLCR) is evaluated in vivo. In 16 patients with permucosal implants in the anterior mandible OLCRs were repeated the same day. The mean total error for the radiographic procedure and analysis was 0.38 mm. The intra-observer error for the determination of the mandibular height by means of the image analysis procedure was 0.16 mm (analysis error). In 12 other patients pairs of radiographs of the same area of the mandible were made using both a "standard" horizontal X-ray beam direction and an individually determined "optimal" horizontal X-ray beam direction; the maximum difference between these two angulations was plus or minus 7.5 degrees. The effect of this different angulation on the height measurements is comparable to the above-mentioned total error of the measurement procedure (positioning error). An accurate positioning of the patient seems important for reliable measurements. The described radiographic (OLCR) and analysis (IBAS) technique can be used relatively simply for clinical studies. The described methods appear to be useful for measuring the mandibular height in longitudinal studies in patients with or without implants.

Cephalometry↗