PubMed Health⌕ Search

PubMed · 15097768

Accommodative and vergence difficulties interfering with image clarity through a binocular indirect ophthalmoscope.

Abstract

PURPOSE: This study sought to identify accommodative and vergence deficiencies that could explain why some students have difficulty seeing clearly when using a binocular indirect ophthalmoscope (BIO) containing its standard +2.00 D lenses. METHODS: A survey was distributed to Illinois College of Optometry 3rd- and 4th-year students. Based on the information supplied by the survey, students were divided into two groups: those who are unable ("BIO plano") and those who are able ("BIO plus") to obtain a clear image with the +2.00 D lenses in their BIO's. Forty-seven subjects participated: 22 in the BIO plano group and 25 in BIO plus group. Two of the authors, masked to subject group, measured all subjects' accommodative amplitudes and facilities, monocular estimation method (MEM) retinoscopy, negative relative accommodation and positive relative accommodation (NRA/PRA), distance and near vergence ranges, distance and near phorias, Worth 4-dot test, and near point of convergence (five times). RESULTS: The Mann-Whitney U analysis of numerical data for the two groups showed a statistically significant difference for accommodative facility in the right eye (p = 0.004). The difference between the two groups approached significance for accommodative facility with both eyes (p = 0.02), facility in the left eye (p = 0.03), distance base-out blur (p = 0.02), near base-out break (p = 0.02), and near base-out recovery (p = 0.04). For all findings in which the difference between the two groups was significant or approached significance, the BIO plus group had higher median values. When subjects were classified by difficulty with the plus side of the flippers during accommodative facility testing, there was a statistically significant difference with both eyes (Fisher exact test, p = 0.003) and with the right eye (p = 0.008) between the BIO plus and BIO plano groups. When subjects were classified by the presence or absence of an accommodative or binocular vision syndrome, categorical data analysis showed the difference between the two groups approached significance, with more BIO plano subjects having syndromes (p = 0.03). CONCLUSION: No one test absolutely defined who would have difficulty with the +2.00 D lenses in the BIO. There are several skills required; less developed plus acceptance and convergence may cause difficulties.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janis Ecklund Winters, Kelly A Frantz, Rachel M Kern. 2004. Accommodative and vergence difficulties interfering with image clarity through a binocular indirect ophthalmoscope.. https://doi.org/10.1097/00006324-200404000-00012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗