PubMed Health⌕ Search

PubMed · 15098590

Does right ventricular apical pacing reduce left ventricular systolic function?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Haruhiko Abe, Yasuhide Nakashima. 2004. Does right ventricular apical pacing reduce left ventricular systolic function?. https://doi.org/10.2169/internalmedicine.43.167

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tissue Doppler echocardiography and biventricular pacing in heart failure: patient selection, procedural guidance, follow-up, quantification of success.

Asynchronous myocardial contraction in heart failure is associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to clinical improvement and reverse remodeling. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram that does not improve despite BVP. QRS width does not predict benefit of BVP and only correlates weakly with echocardiographically determined myocardial asynchrony. Determination of asynchrony by Tissue Doppler echocardiography seems to be the best predictor for improvement after BVP, although no consensus on the optimal method to assess asynchrony has been achieved yet. Our own preliminary results show the usefulness of Tissue Doppler Imaging and Tissue Synchronization Imaging to document acute and sustained improvement after BVP. To date, all studies evaluating Tissue Doppler in BVP were performed retrospectively and no prospective studies with patient selection for BVP according to echocardiographic criteria of asynchrony were published yet. We believe that these new echocardiographic tools will help to prospectively select patients for BVP, help to guide implantation and to optimize device programming.

Cardiac Pacing, Artificial↗

Systematic review: cardiac resynchronization in patients with symptomatic heart failure.

BACKGROUND: Even with optimal pharmacotherapy, symptomatic heart failure is associated with substantial morbidity and mortality. PURPOSE: To determine the efficacy and safety of cardiac resynchronization therapy in adults with advanced systolic heart failure. DATA SOURCES: The Cochrane Central Register of Controlled Trials (2002, volume 4), MEDLINE (1980-2003), EMBASE (1980-2003), other electronic databases, and U.S. Food and Drug Administration reports. We contacted primary study authors and device manufacturers, and we hand searched bibliographies of relevant papers and conference proceedings. STUDY SELECTION: Randomized, controlled clinical trials for efficacy and controlled trials plus prospective cohort studies for safety. DATA EXTRACTION: Two reviewers chose studies and extracted data independently; random-effects models were used for analyses. DATA SYNTHESIS: Nine trials were included in the efficacy review (3216 patients). All trial participants had reduced ejection fraction and prolonged QRS duration, and 85% had New York Heart Association (NYHA) class III or IV symptoms. Cardiac resynchronization therapy improved ejection fraction (weighted mean difference, 0.035 [95% CI, 0.015 to 0.055]), quality of life (weighted mean reduction in score on the Minnesota Living with Heart Failure Questionnaire, 7.6 points [CI, 3.8 to 11.5 points]), and function (58% vs. 37% of patients improved by at least 1 NYHA class). Heart failure hospitalizations were reduced by 32% (relative risk [RR], 0.68 [CI, 0.41 to 1.12]), with benefits most marked in patients with NYHA class III or IV symptoms at baseline (RR, 0.65 [CI, 0.48 to 0.88]; number needed to treat for benefit [NNT(B)], 12). All-cause mortality was reduced by 21% (RR, 0.79 [CI, 0.66 to 0.96]; NNT(B), 24), driven largely by reductions in death from progressive heart failure (RR, 0.60 [CI, 0.36 to 1.01]). Eighteen studies (total of 3701 patients with cardiac resynchronization devices) were included in the safety review. Implant success rate was 90% (CI, 89% to 91%), and 0.4% of patients died during implantation (CI, 0.2% to 0.7%). Over a median 6-month follow-up, leads dislodged in 9% of patients (CI, 7% to 10%) and mechanical malfunctions occurred in 7% (CI, 5% to 8%). LIMITATIONS: These trials enrolled only patients with heart failure with NYHA class III or IV symptoms despite medical therapy, a prolonged QRS duration, and reduced ejection fraction; in addition, experienced providers implanted the devices. Because all but one of these trials randomly assigned patients after device implantation, their results may overestimate the potential benefits of cardiac resynchronization. Finally, since few patients in these trials had bradyarrhythmias or atrial fibrillation, the role of cardiac resynchronization in such patients is uncertain. CONCLUSIONS: In selected patients with heart failure, cardiac resynchronization therapy improves functional and hemodynamic status, reduces heart failure hospitalizations, and reduces all-cause mortality.

Cardiac Pacing, Artificial↗

Cost-effectiveness of cardiac resynchronization therapy in patients with symptomatic heart failure.

BACKGROUND: Heart failure is a common, costly, and debilitating illness. Resynchronization of ventricular contraction in patients with heart failure improves ejection fraction. The long-term morbidity and costs associated with such cardiac resynchronization therapy remain unclear. OBJECTIVE: To assess the incremental cost-effectiveness of cardiac resynchronization therapy. DESIGN: Markov model with Monte Carlo simulation. Future costs and effects were discounted at 3%. DATA SOURCES: Effects data were obtained from a concurrent systematic review. Health-related quality-of-life and cost data were obtained from publicly available data or from surveys. TARGET POPULATION: Patients with reduced ventricular function and prolonged QRS. TIME HORIZON: Lifetime. PERSPECTIVE: U.S. health care system. INTERVENTIONS: Cardiac resynchronization therapy versus medical therapy. OUTCOME MEASURES: Quality-adjusted life-years (QALYs), costs, and incremental cost-effectiveness. RESULTS OF BASE-CASE ANALYSIS: Medical therapy yielded a median of 2.64 (interquartile range, 2.47 to 2.82) discounted QALYs and a median discounted lifetime cost of 34,400 dollars (interquartile range, 31,100 dollars to 37,700 dollars). Cardiac resynchronization therapy was associated with a median incremental cost of 107,800 dollars(interquartile range, 79,800 dollars to 156,500 dollars) per additional QALY. RESULTS OF SENSITIVITY ANALYSIS: Results were sensitive to changes in several variables, including the relative risk for death or hospitalization. LIMITATIONS: These results apply to patients who meet the inclusion criteria of the currently completed trials. CONCLUSIONS: The incremental cost per QALY for cardiac resynchronization is similar to that of other commonly used interventions but is sensitive to changes in several key variables. Resynchronization therapy should not be considered in patients with comorbid illness that shortens life expectancy.

Cardiac Pacing, Artificial↗