PubMed Health⌕ Search

PubMed · 15193110

Thermal analysis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sergey Vyazovkin. 2004-06-15. Thermal analysis.. https://doi.org/10.1021/ac040054h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Peroxyl radical clocks.

A series of peroxyl radical clocks has been developed and calibrated based on the competition between the unimolecular beta-fragmentation (k(beta)) of a peroxyl radical and its bimolecular reaction with a hydrogen atom donor (k(H)). These clocks are based on either methyl linoleate or allylbenzene and were calibrated directly with alpha-tocopherol or methyl linoleate, which have well-established rate constants for reaction with peroxyl radicals (k(H-tocopherol) = 3.5 x 10(6) M(-1) s(-1), k(H-linoleate) = 62 M(-1) s(-1)). This peroxyl radical clock methodology has been successfully applied to determine inhibition and propagation rate constants ranging from 10(0) to 10(7) M(-1) s(-1).

Calibration↗

Coupled two-step microextraction devices with derivatizations to identify hydroxycarbonyls in rain samples by gas chromatography-mass spectrometry.

Coupling a two-step liquid-phase microextraction (LPME) with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine/bis(trimethylsilyl)trifluoroacetamide (PFBHA)/(BSTFA) derivatization was developed to detect hydroxycarbonyls in rainwater samples using gas chromatography-mass spectrometry (GC-MS). LPME provides a fast and inexpensive pre-concentration, and miniaturized extraction to analyze the target compounds rainwater samples. Derivatization techniques offer a clear method to identify target compounds. The hydroxycarbonyls were determined using two-step derivatizations. Dynamic-LPME was applied in the first derivatization, and head-space single drop derivatization was employed in the second reaction. The LODs varied from 0.023 to 4.75 microg/l. The calibration curves were linear for at least two orders of magnitude with R2>or=0.994. The precision was within 6.5-12%, and the relative recoveries in rainwater were more than 89% (the amount added ranged from 0.3 to 15 microg/l). A field sample was found to contain 2.54 microg/l of hydroxyacetone and 0.110 microg/l of 3-hydroxy-2-butanone. Hydroxyacetone was also detected in one of the tested samples at a concentration of 2.39 microg/l.

Calibration↗

Capillary gas chromatographic determination of phenylpropanolamine in pharmaceutical preparation.

Analytical procedure has been developed for the gas chromatographic determination of phenylpropanolamine (PPA) using trifluoroacetylacetone (FAA) as derivatizing reagent. Elution is carried out from the column HP-5 (30 mx0.32 mm i.d.) with film thickness 0.25 microm at initial column temperature 70 degrees C for 5 min, followed by heating rate 10 degrees C/min up to 120 degrees C. Injection port temperature was maintained at 270 degrees C. Nitrogen flow rate was 2 ml/min and detection was by FID. The linear calibration curve was obtained with 30-150 microg/ml PPA with detection limit of 6.0 microg/ml. The method was used for the determination of PPA from Sinutab and Tavegyl-D tablets. The relative standard deviation (R.S.D.) for the analysis of pharmaceutical preparation was obtained within 0.4-0.9%.

Calibration↗