PubMed Health⌕ Search

PubMed · 15255534

A three-axis accelerometer.

Abstract

The development of a three-axis accelerometer that can simultaneously measure acceleration in all three directions is to be utilised in a range of emerging applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Diana Hodgins. 2004. A three-axis accelerometer.. https://pubmed.ncbi.nlm.nih.gov/15255534/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Numerical analysis of maximal bat performance in baseball.

Metal baseball bats have been experimentally demonstrated to produce higher ball exit velocity (BEV) than wooden bats. In the United States, all bats are subject to BEV tests using hitting machines that rotate the bat in a horizontal plane. In this paper, a model of bat-ball impact was developed based on 3-D translational and rotational kinematics of a swing performed by high-level players. The model was designed to simulate the maximal performance of specific models of a wooden bat and a metal bat when swung by a player, and included material properties and kinematics specific to each bat. Impact dynamics were quantified using the finite element method (ANSYS/LSDYNA, version 6.1). Maximum BEV from both a metal (61.5 m/s) and a wooden (50.9 m/s) bat exceeded the 43.1 m/s threshold by which bats are certified as appropriate for commercial sale. The lower BEV from the wooden bat was attributed to a lower pre-impact bat linear velocity, and a more oblique impact that resulted in a greater proportion of BEV being lost to lateral and vertical motion. The results demonstrate the importance of factoring bat linear velocity and spatial orientation into tests of maximal bat performance, and have implications for the design of metal baseball bats.

Acceleration↗

Lightweight low-profile nine-accelerometer package to obtain head angular accelerations in short-duration impacts.

Despite recognizing the importance of angular acceleration in brain injury, computations using data from experimental studies with biological models such as human cadavers have met with varying degrees of success. In this study, a lightweight and a low-profile version of the nine-accelerometer system was developed for applications in head injury evaluations and impact biomechanics tests. The triangular pyramidal nine-accelerometer package (PNAP) is precision-machined out of standard aluminum, is lightweight (65 g), and has a low profile (82 mm base width, 35 mm vertex height). The PNAP assures accurate orthogonal characteristics because all nine accelerometers are pre-aligned and attached before mounting on a human cadaver preparation. The feasibility of using the PNAP in human cadaver head studies is demonstrated by subjecting a specimen to an impact velocity of 8.1 m/s and the resultant angular acceleration peaked at 17 krad/s2. The accuracy and the high fidelity of the PNAP device at high and low angular acceleration levels were demonstrated by comparing the PNAP-derived angular acceleration data with separate tests using the internal nine-accelerometer head of the Hybrid III anthropomorphic test device. Mounting of the PNAP on a biological specimen such as a human cadaver head should yield very accurate angular acceleration data.

Acceleration↗

Precision of measurements of physical workload during standardised manual handling. Part II: Inclinometry of head, upper back, neck and upper arms.

For measuring the physical exposure/workload in studies of work-related musculoskeletal disorders, direct measurements are valuable. However, the between-days and between-subjects variability, as well as the precision of the method per se, are not well known. In a laboratory, six women performed three standardised assembly tasks, all of them repeated on three different days. Triaxial inclinometers were applied to the head, upper back and upper arms. Between-days (within subjects) and between-subjects (within tasks) variance components were derived for the 10th, 50th and 90th percentiles of the angular and the angular velocity distributions, and for the proportion of time spent in predefined angular sectors. For percentiles of the angular distributions, the average between-days variability was 3.4 degrees , and the between-subjects variability 4.0 degrees . For proportion of time spent in angular sectors, the variability depended on the percentage of time spent in the sector; the relative variability was scattered and large, on average 103% between days and 56% between subjects. For the angular velocity percentiles, the average between-days variability was 7.9%, and the average between-subjects variability was 22%. The contribution of the measurement procedure per se to the between-days variability, i.e., the imprecision of the method, was small: less than 2 degrees for angles and 3% for angular velocity.

Acceleration↗