PubMed Health⌕ Search

PubMed · 15298789

Optimizing a linear algorithm for real-time robotic control using chronic cortical ensemble recordings in monkeys.

Abstract

Previous work in our laboratory has demonstrated that a simple linear model can be used to translate cortical neuronal activity into real-time motor control commands that allow a robot arm to mimic the intended hand movements of trained primates. Here, we describe the results of a comprehensive analysis of the contribution of single cortical neurons to this linear model. Key to the operation of this model was the observation that a large percentage of cortical neurons located in both frontal and parietal cortical areas are tuned for hand position. In most neurons, hand position tuning was time-dependent, varying continuously during a 1-sec period before hand movement onset. The relevance of this physiological finding was demonstrated by showing that maximum contribution of individual neurons to the linear model was only achieved when optimal parameters for the impulse response functions describing time-varying neuronal position tuning were selected. Optimal parameters included impulse response functions with 1.0- to 1.4-sec time length and 50- to 100-msec bins. Although reliable generalization and long-term predictions (60-90 min) could be achieved after 10-min training sessions, we noticed that the model performance degraded over long periods. Part of this degradation was accounted by the observation that neuronal position tuning varied significantly throughout the duration (60-90 min) of a recording session. Altogether, these results indicate that the experimental paradigm described here may be useful not only to investigate aspects of neural population coding, but it may also provide a test bed for the development of clinically useful cortical prosthetic devices aimed at restoring motor functions in severely paralyzed patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Johan Wessberg, Miguel A L Nicolelis. Optimizing a linear algorithm for real-time robotic control using chronic cortical ensemble recordings in monkeys.. https://doi.org/10.1162/0898929041502652

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Association of different prediction methods for determination of the efficiency and selectivity on neuron-based sensors.

A technique has been developed to determine the efficiency and the selectivity of a single neuron-based sensor in identifying the nature of the chemical agents in an unknown sample. This has been achieved by exploiting the unique electrical identifiers, also known as "signature patterns", generated by the neuronal cell membrane. These were generated based on the variations to the extracellular electrical activity, due to the effect of a broad range of chemical agents. We demonstrate the prediction capability of the sensor in identifying the nature of an unknown test sample from a combination of three chemical agents, namely, ethanol, pyrethroid, and hydrogen peroxide. This was achieved through a two-step process. The first step was experimentally achieved by in situ recording of the changes to the extracellular electrical activity from the sensing sites or the array of microelectrodes that form the platform for patterning neurons. Simultaneous optical characterization of the cell array during the sensing process was performed to identify the associated physiological changes. The second step was mathematical and was based on developing a library of signature patterns for a set of concentrations of the various combinations of the three chemical agents. Two variants of the nearest neighbor algorithm scheme - (a) partial distance search method, and (b) search tree method, were implemented for the accurate detection of all the components with varying concentrations in the test samples of unknown nature. This technique exhibits reliability in identification up to parts-per-billion (ppb) sensitivity. The capability of standardization of this technique for potential commercial applications is also discussed.

Action Potentials↗

Functional verification of pulse frequency modulation-based image sensor for retinal prosthesis by in vitro electrophysiological experiments using frog retina.

The functioning of a 16 x 16 pixel pulse frequency modulation (PFM) image sensor for retinal prosthesis is verified through in vitro electrophysiological experiments using detached frog retinas. This image sensor is a prototype for demonstrating the application to in vitro electrophysiological experiments. Each pixel of the image sensor consists of a pulse generator (PFM photosensor), a stimulus circuit, and a stimulus electrode (Al bonding pad). The image sensor is fabricated using standard 0.6 microm CMOS technology. For in vitro electrophysiological experiments, a Pt/Au stacked electrode is formed on the Al bonding pad of each pixel and the entire sensor is fixed in epoxy resin. The PFM image sensor is confirmed experimentally to provide electrical stimulus to the retinal cells in a detached frog retina.

Action Potentials↗

An in vivo study of tricalcium phosphate and glutaraldehyde crosslinking gelatin conduits in peripheral nerve repair.

In order to modulate the mechanical properties of gelatin, we previously developed a biodegradable composite composed by tricalcium phosphate and glutaraldehyde crosslinking gelatin (GTG) feasible for surgical manipulation. In this study, we evaluated the in vivo applications of GTG conduit for peripheral nerve repair. The effect of sciatic nerve reconstruction was compared between resorbable permeable GTG conduits and durable impermeable silicone tubes. Traditional methods of assessing nerve recovery following peripheral nerve repair including histomorphometric and electrophysiologic features were conducted in our study. In addition, autotomy score and sciatic function index (SFI) in walking tract analysis were used as additional parameters for assessing the return of nerve function. Twenty-four weeks after sciatic nerve repair, the GTG conduits were harvested. Microscopically, regeneration of nerves was observed in the cross-section at the mid portion of all implanted GTG conduits. The cross-sectional area of regenerated nerve of the GTG group was significant larger than that of the silicone group. In the compound muscle action potentials (CMAP), the mean recovery index of CMAP amplitude was 0.24 +/- 0.02 for the silicone group, 0.41 +/- 0.07 for the GTG group. The mean SFI increased with time in the GTG group during the evaluation period until 24 weeks. Walking tract analysis showed a higher SFI score in the GTG group at both 12 and 24 weeks. The difference reached a significant level at 24 weeks. Thus, the histomorphometric, electrophysiologic, and functional assessments demonstrate that GTG can be a candidate for peripheral nerve repair.

Action Potentials↗