PubMed Health⌕ Search

PubMed · 15328649

[Quantitative trabeculectomy].

Abstract

The outcomes of the trabeculectomy which finally establish one normal ocular pressure are presented. The surgery method is adjustment of the thickness of the sclera, fragment depending on the initial ocular pressure. The evacuation of the aqueous humor after trabeculectomy is indirect proportionally with the thickness of the scleral fragment. The method was used in 36 eyes with different patterns of glaucoma. At this patients the initial ocular pressure was until 50 mm Hg. In 72.2% from cases was necessary only one surgery intervention for maintain the ocular pressure, without auxiliary drugs; two eyes underwent still one surgical intervention and in seven eyes was necessary auxiliary hypotensor drugs. The outcomes were good in 97.2% from cases. One failure was obtained in one eye with closed angle glaucoma where the trabeculectomy was complicated with malignant glaucoma. Complications were hypema, atalamy with or without choroidal detachment and high ocular pressure. All complications were improved after conservative treatment excepting the case with malignant glaucoma.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Sireteanu, C Tudor, L Dumbrăveanu, A Sireteanu. 1997. [Quantitative trabeculectomy].. https://pubmed.health/record/pubmed%3A15328649/quantitative-trabeculectomy

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗