Thermal comfort in practice.

Abstract

UNLABELLED: Since the early twentieth century when air-conditioning began penetrating the market in a serious way, there has been a need for human factors research upon which HVAC engineering practice could be based. Now we have nearly a century of thermal comfort research from climate chambers and much has been learnt in that time. By stripping the research problem back to essential cause-and-effect variables, climate chamber methods have delivered results that are amenable to rigorous data analyses leading to unequivocal conclusions. However, in the minds of HVAC practitioners there are persistent doubts about the experiential realism of the chamber methodology, and the external validity of their findings, in particular, their relevance to building occupants going about their normal daily routines in fully-engineered indoor climatic environments. In response to this methodological concern in the 1990s, ASHRAE commissioned a series of thermal comfort studies aimed at field validating the findings of climate chamber research and the HVAC standards based upon them in a variety of climatic contexts around the world. This paper discusses the methodological benefits and constraints of conventional climate chamber research in comparison to the field-based alternative. In particular, issues such as sample size and demographics, research design, instrumentation and indoor climatic measurement procedures, questionnaires, clothing insulation and metabolic rate assessment techniques are analyzed. The discussion of methodology is then extended to the discipline of environmental psychology, which should have made a much more significant contribution to the topic of thermal comfort, and yet has remained relatively silent. The paper finishes by considering why engineers, most notably P.O. Fanger, have come to dominate a research topic that falls so clearly within the scope of psychology. HVAC engineering is the profession most directly occupied in the practice of thermal comfort, and therefore an engineer such as Fanger has been ideally qualified to design and conduct research, and even more important, presents its results in a way most directly useful to thermal comfort practitioners. PRACTICAL IMPLICATIONS: The paper gives practical advice on evaluating and designing for thermal comfort.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R de Dear. 2004. Thermal comfort in practice.. https://doi.org/10.1111/j.1600-0668.2004.00270.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monitoring of biofilm-associated Legionella pneumophila on different substrata in model cooling tower system.

Cooling towers have the potential to develop infectious concentrations of Legionella pneumophila. Legionella counts increases where biofilm and warm water temperatures are present. In this study, biofilm associated L. pneumophila and heterotrophic bacteria were compared in terms of material dependence. Model cooling tower system was experimentally infected by L. pneumophila standard strain and monthly monitored. Different materials were tested for a period of 180 days. The lowest L. pneumophila and heterotrophic plate counts were measured on plastic polymers, whereas L. pneumophila and heterotrophic bacteria were accumulated rapidly on galvanized steel surfaces. It can be concluded that selection of plastic polymers, as a manufacturing material, are suitable for recirculating water systems.

Air Conditioning↗

Real-time evaluation of ventilation filter-bank systems.

This study evaluated two government facility ventilation systems. One was a metropolitan government office complex with a recirculation system where outside air was the makeup air; the other was a NIOSH facility that used 100% outside air with no recirculation. The methodology employed was a modified American Society of Agricultural Engineers standard (S525) for testing total enclosure filtration efficiency, in agricultural tractor cabs, with optical particle counters (OPC). The low-efficiency bag filters were tested when new and after being in the ventilation system for 3 months. The replacement medium-efficiency filters were evaluated for 6 months (the manufacturer's suggested change-out schedule). These eight-chamber, medium-efficiency filters had an increased filter surface area that resulted in increased airflow through the system. Unfortunately, these filters contained electrostatic filter media and lost filtration efficiency rapidly, which was subsequently confirmed in a 30-day study conducted to determine an appropriate change-out schedule for the eight-chamber bag filters. The study determined that less than 6 months' use was justified due to the reduced efficiency of the electrostatic filter media. The NIOSH facility's air handler #8 (100% outside air unit) was upgraded from electrostatic bag filters, which had a suggested 9-month change-out schedule, to V Bank mechanical, wet-laid, glass fiber filters. The results of a 3-year evaluation showed that the V Bank filters had better filter efficiency after 3 years of service than the electrostatic filters had at 9 months. Both studies employed matched OPC instruments to reduce instrument-to-instrument bias. The methodology is adaptable to monitoring the total efficiency of most air filtration systems, and results can help make decisions about upgrading filter performance.

Air Conditioning↗

Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems.

We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.

Air Conditioning↗