PubMed Health⌕ Search

PubMed · 15333626

Strain differences in murine ventilatory behavior persist after urethane anesthesia.

Abstract

Differences in breathing pattern between awake C57BL/6J (B6) and A/J mice are such that A/J mice breathe slower, deeper, and with greater variability than B6. We theorized that urethane anesthesia, by affecting cortical and subcortical function, would test the hypothesis that strain differences require a fully functional neuroaxis. We anesthetized B6 and A/J mice with urethane, placed them in a whole-body plethysmograph, and measured the durations of inspiration and expiration, respiratory frequency (Fr), and peak amplitude during exposure to room air (21% O2), hyperoxia (5 min, 100% O2), hypoxia (5 min, 8% O2), and posthypoxic reoxygenation (5 min, 100% O2). Breathing variability was assessed by calculating the coefficient of variation (CV) and by applying spatial statistics to Poincaré plots constructed from the timing and amplitude data. Even though Fr in anesthetized B6 and A/J mice was greater than that for unanesthetized animals, anesthetized A/J mice still breathed slower, deeper, and with greater variability than B6 mice at rest and during hyperoxia. During the fourth minute of hypoxia, Fr and its CV were not significantly different between strains. Even though Fr was similar between strains immediately after hypoxia, its CV was significantly greater for B6 than A/J mice. Posthypoxic Fr was significantly less than baseline Fr in B6 but not A/J mice, and the CV for posthypoxic Fr was greater for B6 but less for AJ mice compared with baseline CV. This difference in patterning was confirmed by spatial statistical analysis. We conclude that strain-specific differences in respiratory pattern and its variability are robust genetic traits. The neural substrate for these differences, at least partially, exists within subcortical structures generating the breathing pattern.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Iahn Gonsenhauser, Christopher G Wilson, Fang Han, Kingman P Strohl, Thomas E Dick. 2004. Strain differences in murine ventilatory behavior persist after urethane anesthesia.. https://doi.org/10.1152/japplphysiol.01346.2003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thin-fiber mechanoreceptors reflexly increase renal sympathetic nerve activity during static contraction.

The renal vasoconstriction induced by the sympathetic outflow during exercise serves to direct blood flow from the kidney toward the exercising muscles. The renal circulation seems to be particularly important in this regard, because it receives a substantial part of the cardiac output, which in resting humans has been estimated to be 20%. The role of group III mechanoreceptors in causing the reflex renal sympathetic response to static contraction remains an open question. To shed some light on this question, we recorded the renal sympathetic nerve responses to static contraction before and after injection of gadolinium into the arterial supply of the statically contracting triceps surae muscles of decerebrate unanesthetized and chloralose-anesthetized cats. Gadolinium has been shown to be a selective blocker of mechanogated channels in thin-fiber muscle afferents, which comprise the afferent arm of the exercise pressor reflex arc. In decerebrate (n = 15) and chloralose-anesthetized (n = 12) cats, we found that gadolinium (10 mM; 1 ml) significantly attenuated the renal sympathetic nerve and pressor responses to static contraction (60 s) after a latent period of 60 min; both responses recovered after a latent period of 120 min. We conclude that thin-fiber mechanoreceptors supplying contracting muscle are involved in some of the renal vasoconstriction evoked by the exercise pressor reflex.

Anesthetics, Intravenous↗