PubMed Health⌕ Search

PubMed · 15350414

Observations on solid phase micro-extraction for MTBE analysis.

Abstract

In a recent study of aqueous phase methyl tertiary butyl ether (MTBE) adsorption onto hydrophobic molecular sieves, the solid phase micro-extraction gas chromatography analytical technique was used to measure MTBE concentrations in water. The method was especially beneficial in measuring MTBE concentrations in the microg/l range, but anomalies were observed that investigators should be aware of before employing this technique. Specifically, it was observed that the calibration of the extraction fiber with known MTBE concentrations was non-linear over all concentration ranges. The technique was not suited to higher concentrations, and dilutions were necessary to increase the working range of the technique. Lastly, the fiber was observed to extract increasingly less MTBE from known standard solutions over time, requiring repeated calibrations to obtain reliable concentrations of unknown samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ayşe Erdem-Senatalar, John A Bergendahl, Robert W Thompson. 2004. Observations on solid phase micro-extraction for MTBE analysis.. https://doi.org/10.1016/j.chemosphere.2004.06.031

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous determination of glycyrrhizin, a marker component in radix Glycyrrhizae, and its major metabolite glycyrrhetic acid in human plasma by LC-MS/MS.

Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.

Calibration↗

A capillary liquid chromatographic/tandem mass spectrometric method for the quantification of gamma-aminobutyric acid in human plasma and cerebrospinal fluid.

A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.

Calibration↗

Chiral analysis of methadone and its major metabolites (EDDP and EMDP) by liquid chromatography-mass spectrometry.

Racemic methadone (MET) is administered to heroin users undergoing methadone maintenance therapy (MMT) in Australia. The enantiomers of methadone possess different pharmacological effects, and the enantioselective metabolism of methadone to its two major metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenyl-1-pyrroline (EMDP) has been demonstrated. Therefore, a stereoselective method capable of quantifying methadone, EDDP and EMDP in biological samples could be of benefit in the monitoring of MMT patients. In particular, the analysis of hair samples would provide a means by which long-term monitoring of MMT patients could be achieved. To date, no HPLC method has been published for the simultaneous separation of the six enantiomers. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the chiral analysis of methadone, EDDP and EMDP was developed using an alpha-glycoprotein (AGP) stationary phase. The method development involved the utilisation of factorial analysis experimental designs and the application of artificial neural networks (ANNs) to model the chromatographic response surfaces. The optimal conditions were determined to be 20mM acetic acid: isopropanol (93:7, pH 7.4), with a flow rate of 0.9mL/min. The method was validated and subsequently applied to the analysis of 20 hair samples collected from MMT patients.

Calibration↗