Inter-laboratory test program (PTI) in 'neutron dosimetry'.

Abstract

The Laboratory of External Dosimetry Studies and Researches (LRDE), associated laboratory to the Bureau National de Métrologie, is strongly involved in the reference establishment and calibration of instruments in neutron radiation fields provided by 241Am-Be, 252Cf and (252Cf + D2O)/Cd sources. In 1997, on the request of COFRAC, the LRDE has managed an Inter-Laboratory Test Program in 'neutron dosimetry' to compare the different standard calibration methods. The transfer instrument used was a "Harwell Monitor N91". The results of the participant were in good agreement but the associated uncertainties need to be revised by some of laboratories. According to the Mutual Recognition Arrangement signed in 1999, laboratories for metrology will have to assure the traceability of their references. In 2003-2005, the LRDE organises, with National Physical Laboratory (UK) and Physikalisch-Techische Bundesanstalt (Germany), an international comparison in 'neutron dosimetry'. Two transfer instruments, a "2202D" rate metre and a "Harwell Monitor N91", will be sent in turn to the participant laboratories for measurements at their own neutron sources facilities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Van-Ryckeghem, G Pelcot, F Suder, Bureau National de Métrologie. 2004. Inter-laboratory test program (PTI) in 'neutron dosimetry'.. https://doi.org/10.1093/rpd%2Fnch193

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Patient dose measurements in diagnostic radiology procedures in Korea.

This study is the first nationwide investigation aimed at estimating the patient dose for radiographic examinations in Korea including gastrointestinal studies, computed tomography and mammography. The survey data from 161 hospitals and the dose data from 32 hospitals were analysed. The third quartile entrance surface dose, dose area product (DAP), weighted CT dose index (CTDIw) and mean glandular dose (MGD) were reported. All the estimated doses were less than the stated International Atomic Energy Agency (IAEA) reference levels for radiographic examinations. However, DAPs for the fluoroscopic examinations had higher dose values than the IAEA reference levels. In addition, the CTDIw and MGD were lower than the IAEA reference levels.

Body Burden↗

The study of new calibration features in the Harshaw TLD system.

The Harshaw TLD system has three key calibration procedures: the Reader, the Dosemeter and the Algorithm. These functions must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosemeter calibration, Harshaw TLD recommends a pre-fade and a post-fade of 24-48 h when calibrating the system for LiF:Mg,Ti type dosemeter. It is also recommended that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the Harshaw TLD models 6600 and 8800 operating systems. These new features are Auto Calibration, Auto QC and Auto Blank, and they give the user the ability to set up the clear-expose-read process to be performed automatically in a sequence for each dosemeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of Auto Calibration/Auto QC to the TLD operation.

Body Burden↗

Proton and photon absorbed-dose conversion coefficients for embryo and foetus from top-down irradiation geometry.

Absorbed-dose conversion coefficients are calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months when the mother's body is exposed to protons and photons from top-down (TOP) direction. It provides data sets in addition to other standard irradiation geometries published previously. The TOP-irradiation geometry is considered here, because high-energy particles are often peaked from the TOP direction onboard aircrafts. The results show that absorbed-doses from high-energy particles could be underestimated significantly if isotropic (ISO) irradiation geometry is assumed. For protons of 100 GeV, absorbed-doses from TOP irradiation are approximately 2.3-2.9 times higher than the doses from ISO irradiation for different foetal ages. For 10 GeV photons, foetal doses from TOP irradiation are approximately 6.8-12 times higher than the doses from ISO irradiation. The coefficients from TOP-irradiation geometry are given in wide energy ranges, from 100 MeV to 100 GeV for protons and from 50 keV to 10 GeV for photons. They can, therefore, be used in various applications whenever exposure from the TOP-irradiation direction is concerned.