PubMed Health⌕ Search

PubMed · 15413329

[Fibrin formation under the electronic microscope].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H BRAUNSTEINER, H FEBVRE. 1950. [Fibrin formation under the electronic microscope].. https://pubmed.ncbi.nlm.nih.gov/15413329/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fibrinolytic properties of lysine-derivatized polyethylene in contact with flowing whole blood (Chandler loop model).

This article reports on the concept of a fibrinolytic surface based on the preferential adsorption of endogenous plasminogen from blood. Data are presented indicating that such a surface, when pretreated with tissue-type plasminogen activator (tPA), is able to dissolve nascent thrombus generated in contact with flowing whole blood. Polyethylene (PE) surfaces were modified by attaching a lysine-containing polymer using photochemical methods as reported previously (McClung et al., J Biomed Mater Res 2000;49:409-414). The lysine residues were bound chemically to the polymer via the alpha-amino groups leaving the epsilon-amino groups free (epsilon-Lys surface). Control surfaces were (a) unmodified PE, (b) PE modified with the coating polymer containing no lysine, and (c) PE modified with the polymer containing lysine bound via the epsilon-amino group. The materials in tubing form were evaluated in contact with nonanticoagulated flowing human whole blood in a modified Chandler Loop experiment. They were first treated with tPA to allow activation of adsorbed plasminogen to plasmin. It was found that thrombus formation was initiated within 15-25 min (depending on donor blood) on all surfaces, as indicated by the formation of platelet aggregates. On the controls (including the lysine-containing material in which the epsilon-amino group was used in the binding reaction) thrombogenesis continued till the tubing was occluded and blood flow ceased. On the epsilon-Lys surface, thrombogenesis was interrupted at various stages depending on the donor blood; in all cases any thrombus generated was dissolved within minutes. It was shown that thrombolysis was due to the fibrinolytic action of plasmin generated at the surface and not to plasmin formed by traces of tPA released into the blood. This work provides further evidence of the efficacy of this approach to the development of a fibrinolytic surface.

Blood↗

Enamel matrix derivative stimulates human gingival fibroblast proliferation via ERK.

Emdogain, a formulation of Enamel Matrix Proteins, is used clinically for periodontal regeneration to stimulate PDL (periodontal ligament), cementum, and bone formation. Its effects on gingival fibroblasts and tissue have not been thoroughly studied. Therefore, we investigated the mechanisms by which Emdogain affects the cell cycle of human gingival fibroblasts. Without serum, Emdogain (50 microg/mL) induced human gingival fibroblast entry into the S phase and DNA synthesis, but not completion of the cell cycle. With low serum concentrations (0.2-0.5%), Emdogain synergistically induced completion of the cell cycle, resulting in increased cell numbers. The mitogenic response to Emdogain depended on Extracellular Regulated Kinase (ERK) activation, which occurred in two waves, peaking after 15 min and 4 to 6 hrs, since it was abolished by U0126, a specific MAPK inhibitor. Inhibition of the second wave was sufficient to abrogate mitogenesis. This study characterized the mitogenic effect of Emdogain on primary human gingival fibroblasts, its cooperation with serum growth factors, and the key mediatory role of the ERK cascade.

Blood↗

Performance evaluation of a new rapid quantitative assay system for measurement of D-dimer in plasma and whole blood: PATHFAST D-dimer.

D-dimer is an indicator for in vivo fibrin formation, reflecting the formation of fibrin crosslinked by factor XIIIa. D-dimer assays are frequently used in emergency situations, such as diagnosis of venous thrombosis and pulmonary embolism, or disseminated intravascular coagulation. In these conditions, short sample turnaround times are essential. The PATHFAST D-dimer assay allows rapid quantitative measurement of D-dimer in plasma and whole blood. The study shows an excellent correlation between whole blood and plasma measurement of D-dimer both in the high range, as well as in the normal range. Intra-assay and inter-assay coefficients of variation (CV) were below 10%. The upper limit of normal (ULN = mean value measured in 100 samples from healthy blood donors + 2 x S.D.) was approximately 1 microg/ml FEU, using the assay-specific calibration. The maximal value measured in 20 replicates of calibrator 1 containing no D-dimer antigen was 0.00052 microg/ml FEU, and this 10-fold lower than the declared detection limit of 0.005 microg/ml FEU. In conclusion, the PATHFAST D-dimer assay is the first automated fully quantitative D-dimer assay, which can use plasma and whole blood as sample materials in parallel.

Blood↗