PubMed Health⌕ Search

PubMed · 15414860

[Blood-groups classification].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V V VLASOV. 1950. [Blood-groups classification].. https://pubmed.ncbi.nlm.nih.gov/15414860/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A systematic review of the clinical effects of reducing dialysate fluid temperature.

BACKGROUND: Intradialytic hypotension (IDH) is a frequent complication of haemodialysis. Reducing the temperature of the dialysis fluid is a simple therapeutic strategy but is relatively underused. This may be due to concerns regarding its effects on symptoms and dialysis adequacy. We performed a systematic review of the literature to examine the effects of cool dialysis on intradialytic blood pressure, and to assess its safety in terms of thermal symptoms and small solute clearance. METHODS: We searched the Cochrane Central Register of Controlled Trials, Medline, Embase, Cumulative Index to Nursing and Allied Health Literature, databases of ongoing trials, the contents of four major renal journals as well as hand-searching reference lists. We included all prospective randomized studies that compared any technique of reducing dialysate temperature with standard bicarbonate dialysis. These techniques included an empirical, fixed reduction of dialysate temperature or use of a biofeedback temperature-control device (BTM) to deliver isothermic dialysis or programmed patient cooling. RESULTS: A total of 22 studies comprising 408 patients were included (16 studies examined a fixed empirical temperature reduction and six examined BTM). All studies were of crossover design and relatively short duration. IDH occurred 7.1 (95% CI, 5.3-8.9) times less frequently with cool dialysis (both fixed reduction and BTM). Post-dialysis mean arterial pressure was higher with cool-temperature dialysis by 11.3 mmHg (95% CI, 7.7-15.0). No studies reported that cool dialysis led to a reduction in dialysis adequacy as assessed by urea clearance. The frequency and severity of thermal-related symptoms were generally reported inadequately. CONCLUSIONS: Reducing the temperature of the dialysate is an effective intervention to reduce the frequency of IDH and does not adversely affect dialysis adequacy. This applies to the fixed reduction of dialysate temperature and BTM. It remains unclear as to what extent cool-temperature dialysis causes intolerable cold symptoms during dialysis. There are no trials comparing fixed empirical temperature reduction with BTM, and no trials examining the long-term effects of cool dialysis on patient outcomes.

Blood↗

DNA extraction using a tetramethyl orthosilicate-grafted photopolymerized monolithic solid phase.

A novel high-capacity, high-efficiency DNA extraction method is described using a photopolymerized silica-based monolithic column in a fused-silica capillary. Development involved investigation of the composition of the sol-gel monomer, fabrication conditions, and surface modifications in order to optimize the binding capacity. Extraction capacity and efficiency with the 3-(trimethoxysilyl)propyl methacrylate (TMSPM) monolith formulations fabricated in capillaries were investigated using a simple three-step procedure consisting of sample loading, washing of the solid phase, and elution of the DNA using a low ionic strength Tris buffer at pH 8. Once the TMSPM monomer concentration was optimized to yield a monolith with maximum test stability (robustness) and minimum back pressure, the monolith surface was modified by the grafting of tetramethyl orthosilicate (TMOS) for increased DNA binding capacity. After the examination of a variety of TMOS concentrations, 85% v/v TMOS was found to be optimal for DNA extraction without any obvious changes to the monolith structure. The reduction of time allowed for TMSPM hydrolysis prior to UV polymerization from 20 to 5 min led to a lower back pressure of the monolith, enabling better TMOS derivatization and therefore higher binding capacity. Minimal buffer volume (as low as 1 muL) was required to elute DNA from the solid phase, providing a DNA concentrating effect potentially important for downstream processes. While experimentation employed monolithic columns that were 12 cm in length, reduction of the length to 2 cm still allowed for a DNA binding capacity of at least 100 ng of prepurified human genomic DNA and extraction efficiencies greater than 85%. Extraction of low sample volumes (submicroliter) of human whole blood were successfully performed, with extraction efficiencies from the 2-cm monolithic column higher than those obtained from a commercial DNA extraction kit. These results position this novel matrix as an attractive alternative for solid-phase extraction of DNA and other biologically active molecules in microscale devices.

Blood↗