PubMed Health⌕ Search

PubMed · 15476957

Translucent fiber post cementation using a light-curing adhesive/composite system: SEM analysis and pull-out test.

Abstract

OBJECTIVES: The performance of both light-curing and dual-cured adhesive/luting systems (as control), when used in combination with translucent fibre posts, was evaluated by means of pull-out test and scanning electron microscopy (SEM ) observation. METHODS: Forty root canal treated teeth were randomly divided into two groups of 20 specimens each. Group 1 light-curing system: Excite and Tetric Flow; Group 2 dual cured system: All Bond 2+RelyX ARC. Translucent, double taper fibre posts were used (2.1/1.4mm diameter). The teeth were stored in NaCl 0.9% solution at 37 degrees C. A week later, the pull-out test was carried out on all specimens. Ten tested specimens for each group and their corresponding posts were processed for SEM observation. Statistical analysis was performed applying one-way analysis of variance (ANOVA) followed by T-test as post-hoc comparison at a significance level set at p<0.05. RESULTS: There is no statistically significant difference (p>0.05) between the light-curing system group (275.2+/-58.9N) and the dual cured one (301.4+/-40.1N). SEM observations confirm a good bond between the dentine and the post whatever the curing method employed. CONCLUSIONS: Dual curing of the All Bond 2+RelyX ARC system seems to be the most appropriate method since it allows to cure even those areas which would not be otherwise reached by light. On the other hand, in apical areas, the incomplete curing of the Excite+Tetric Flow system could improve the post adaptation and allow the achievement of both an improved apical seal and a more even distribution of the stress along the canal walls.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Luca Giachetti, Daniele Scaminaci Russo, Fabio Bertini, Valentina Giuliani. 2004. Translucent fiber post cementation using a light-curing adhesive/composite system: SEM analysis and pull-out test.. https://doi.org/10.1016/j.jdent.2004.06.004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Healing substrates with mobile, particle-filled microcapsules: designing a 'repair and go' system.

We model the rolling motion of a fluid-driven, particle-filled microcapsule along a heterogeneous, adhesive substrate to determine how the release of the encapsulated nanoparticles can be harnessed to repair damage on the underlying surface. We integrate the lattice Boltzmann model for hydrodynamics and the lattice spring model for the micromechanics of elastic solids to capture the interactions between the elastic shell of the microcapsule and the surrounding fluids. A Brownian dynamics model is used to simulate the release of nanoparticles from the capsule and their diffusion into the surrounding solution. We focus on a substrate that contains a damaged region (e.g. a crack or eroded surface coating), which prevents the otherwise mobile capsule from rolling along the surface. We isolate conditions where nanoparticles released from the arrested capsule can repair the damage and thereby enable the capsules to again move along the substrate. Through these studies, we establish guidelines for designing particle-filled microcapsules that perform a 'repair and go' function and thus, can be utilized to repair damage in microchannels and microfluidic devices.

Adhesives↗

Microtensile bond strength of composite resin to human enamel prepared using erbium: Yttrium aluminum garnet laser.

The Erbium: Yttrium Aluminum Garnet (YAG) laser used for preparation of cavity can alter the substrate and it could influence the bond strength of enamel. The aim of this in vitro study was to evaluate the influence of Er:YAG laser's energy using microtensile bond test. Three groups were obtained (cavity preparation) and each group was divided into two subgroups (adhesive system). After that the adhesive protocol was performed, sections with a cross-sectional area of 0.8 mm2 (+/-0.2 mm2) were obtained. The specimens were mounted in a universal testing machine (0.5 mm/min). Statistical analysis showed a decrease in bond strength for lased groups (p < 0.01) and when the total-etching adhesive system was used the laser 300 mJ subgroup showed higher bond strength compared to the laser 250 mJ (p < 0.01). It was concluded that the cavities prepared using laser appear less receptive to adhesive procedures than conventional bur-cut cavities.

Adhesives↗