PubMed Health⌕ Search

PubMed · 1549045

Image reconstruction for echo planar imaging with nonequidistant k-space sampling.

Abstract

Echo planar imaging is characterized by scanning the 2D k-space after a single excitation. Different sampling patterns have been proposed. A technically feasible method uses a sinusoidal readout gradient resulting is measured data that does not sample k-space in an equidistant manner. In order to employ a conventional 2D-FFT image reconstruction, the data have to be converted to a cartesian grid. This can be done either by interpolation or alternatively by a generalized transformation. Filtering methods are described to minimize ghosting artifact that is typical in echo planar imaging. Results both from computer simulation and from experiments will be presented. Experimental images were obtained using a 2-T whole-body research system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Bruder, H Fischer, H E Reinfelder, F Schmitt. 1992. Image reconstruction for echo planar imaging with nonequidistant k-space sampling.. https://doi.org/10.1002/mrm.1910230211

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗