PubMed Health⌕ Search

PubMed · 15565161

Material gains.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Myrna Watanabe. 2004-11-25. Material gains.. https://doi.org/10.1038/nj7016-532a

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Morphology and gelation of thermosensitive chitosan hydrogels.

The morphology of physical hydrogels is often difficult to examine due to the delicate nature of the system and therefore has not been studied in detail. Chitosan/GP (glycerophosphate salt) is a significant hydrogel in the biomedical and cosmetic fields as it is thermosensitive and contains less than 5% polysaccharide. The morphology of this system was examined with laser scanning confocal microscopy (LSCM) to image the gel morphology. The images indicate that the gel is quite heterogeneous, and power spectra reveal a fractal-like morphology. A study of composition found that increasing chitosan concentration increased the amount of polymer-rich phase present in the gel, and that the smallest aggregates decreased in size.

Biocompatible Materials↗

Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants.

The corrosion and dissolution of high- and low-carbon CoCrMo alloys, as used in orthopedic joint replacements, were studied by immersing samples in phosphate-buffered saline (PBS), water, and synovial fluid at 37 degrees C for up to 35 days. Bulk properties were analyzed with a fine ion beam microscope. Surface analyses by X-ray photoelectron spectroscopy and Auger electron spectroscopy showed surprisingly that synovial fluid produced a thin oxide/hydroxide layer. Release of ions into solution from the alloy also followed an unexpected pattern where synovial fluid, of all the samples, had the highest Cr concentration but the lowest Co concentration. The presence of carbide inclusions in the alloy did not affect the corrosion or the dissolution mechanisms, although the carbides were a significant feature on the metal surface. Only one mechanism was recognized as controlling the thickness of the oxide/hydroxide interface. The analysis of the dissolved metal showed two mechanisms at work: (1) a protein film caused ligand-induced dissolution, increasing the Cr concentration in synovial fluid, and was explained by the equilibrium constants; (2) corrosion at the interface increased the Co in PBS. The effect of prepassivating the samples (ASTM F-86-01) did not always have the desired effect of reducing dissolution. The release of Cr into PBS increased after prepassivation. The metal-synovial fluid interface did not contain calcium phosphate as a deposit, typically found where samples are exposed to calcium rich bodily fluids.

Biocompatible Materials↗

Interactions between self-assembled polyelectrolyte shells and tumor cells.

Layer-by-layer self-assembled polyelectrolyte shells are a new class of micro/nanocapsules with unique physicochemical properties for potential applications in drug/gene delivery. The objective of this study was to investigate the interactions of polyelectrolyte shells ( approximately 1 mum in diameter) with MCF-7 breast cancer cells and identify key parameters that affect such interactions. Tailoring of surface properties of polyelectrolyte shells was achieved by choosing different outermost layer materials, including cationic polymers, anionic polymers, and lipid bilayers. Different surface compositions led to a wide range of electrostatic potentials from -46 to +47 mV in phophate-buffered saline buffer. Confocal microscopy studies showed that the polyelectrolyte shells were internalized into the cell cytoplasm, but not into the nuclei. Correlation of cell uptake with shell surface compositions was complicated by the adsorption of serum proteins on the surface of polyelectrolyte shells, particularly polycation-coated shells. To prevent protein adsorption, poly(ethylene glycol) (PEG) grafted poly(ethyleneimine) (PEI) copolymers (1:1, 1:5, 1:10 graft ratios) were synthesized and introduced on the shell surface. Shells coated with PEI-PEG copolymers effectively reduced protein adsorption whereas PEI-PEG copolymers with lower graft ratios achieved higher cell uptake efficiency after 24 h of incubation with MCF-7 cells.

Biocompatible Materials↗