[Digital fluorograph with automatic exposition].

Abstract

Discussed in the paper is a system of automatic exposition choice in a digital fluorograph designed by the "Gelpik" company, Moscow. The perspective equipment variation is as follows: intensifying screen + optic system + charge-communication device-matrix.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A B Mishkinis, B M Kanter. [Digital fluorograph with automatic exposition].. https://pubmed.ncbi.nlm.nih.gov/15568514/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The pain associated with intraarticular hyaluronic acid injections for trapeziometacarpal osteoarthritis.

Trapeziometacarpal osteoarthritis predominantly affects middle-aged women. Most cases with rhizarthrosis can be managed successfully by conservative means. The purpose of this prospective study was to evaluate pain and tolerability of viscosupplementation therapy with hyaluronic acid (HA) for trapeziometacarpal osteoarthritis. Groups A and B consisted of eight patients each with Eaton stage 3 or 4 rhizarthrosis, who underwent one cycle of three injections of (one per week) 0.3 cm3 sodium hyaluronate. The injections for group A were under fluoroscopy control, but fluoroscopy was not used in group B. Pain and tolerability of both groups A and B were measured and compared. The patients of the groups were also asked to evaluate the tolerability of the treatment. The results suggested that HA injection in the carpometacarpal joint is a tolerable procedure but the patients complained of pain and discomfort during the injections. The pain in group A was much greater than in group B. Viscosupplementation for the treatment of trapeziometacarpal osteoarthritis is a viable treatment option for stages 3 and 4 patients when they do not want to be operated on. It is a tolerable but not a painless procedure especially when it is done without fluoroscopy control. We recommend giving injections under fluoroscopy control.

Fluoroscopy↗

Evaluating mobility for radiotherapy planning of lung tumors: a comparison of virtual fluoroscopy and 4DCT.

PURPOSE: Fluoroscopy is widely used for evaluating tumor mobility in radiotherapy planning. Lung tumor mobility was scored using virtual fluoroscopy, and this was compared to mobility derived from contoured tumors in all phases of a respiration-correlated (or 4D) CT scan. METHODS AND MATERIALS: 4DCT datasets were reviewed and 29 patients were identified in whom tumors were visible on anterior-posterior fluoroscopy views. Mobility in all directions was estimated on fluoroscopy movie loops by four clinicians. These results were compared to mobility measured from contoured tumor volumes in all phases of the same 4DCT. Internal target volumes (ITV) were generated for both approaches. RESULTS: In eight patients, fluoroscopy did not allow for tumor mobility to be assessed in at least one direction. No significant inter-clinician variation was observed with respect to fluoroscopic assessment of mobility. Clinicians systematically overestimated mobility in all three directions (p<0.05). The mean ITVs derived using fluoroscopy were 52.2% larger than those derived using 4DCT contours, but the individual ITVs were smaller in three patients. CONCLUSION: Use of virtual fluoroscopy generally overestimates the mobility of visible lung tumors, and results in irradiation of unnecessarily large target volumes. In contrast, use of 4DCT minimizes the risk of normal tissue toxicity.

Fluoroscopy↗

The left hand as a model for the right atrium: a simple teaching tool.

AIMS: Knowledge of the complex three-dimensional anatomy of the right atrium is mandatory for the electrophysiologist and interventional cardiologist, but its understanding remains difficult. We hypothesized that the left hand, loosely clenched, is a good three-dimensional model to understand the position of the different anatomical and electrical regions in the right atrium. For validation, we compared the hand with an endocast that had been prepared from an adult human right atrium and with a three-dimensional electro-anatomical CT image of the right atrium. METHODS AND RESULTS: Views of the left hand were photographed from various angles to replicate as closely as possible the standard fluoroscopic views. Using the nomenclature of the bones of the hand, we assigned the different regions of the hand to represent regions and structures of the right atrium. An endocast was prepared from an adult human right atrium. A three-dimensional electro-anatomical right atrial map with CT integration (CartoMerge) was used as the gold standard for the exact localization of electrical regions such as the sinus node (SN), bundle of His, and slow pathway region. Using the left hand, it is possible to mark the free wall, terminal crest, appendage, septal surface, oval fossa and orifices of the caval veins, tricuspid valve, and coronary sinus. We also marked the anticipated locations of the SN, His bundle, triangle of Koch, slow pathway region, inferior isthmus, and right atrial insertion of Bachmann's bundle. When compared with an endocast and a three-dimensional electro-anatomical CT image, the position and orientation of the marked regions were deemed to be anatomically correct. CONCLUSION: Compared with an endocast and a CT-guided electro-anatomical reconstruction of the right atrium, the left hand is a reliable model to understand the position and orientation of the different anatomical and electrical regions in the right atrium. Although an oversimplification of the complex right atrial anatomy, this model is 'handy' to understand, guide, and teach electrophysiological and interventional procedures.

Fluoroscopy↗