PubMed Health⌕ Search

PubMed · 15606412

Methods for the statistical analysis of binary data in split-cluster designs.

Abstract

Split-cluster designs are frequently used in the health sciences when naturally occurring clusters such as multiple sites or organs in the same subject are assigned to different treatments. However, statistical methods for the analysis of binary data arising from such designs are not well developed. The purpose of this article is to propose and evaluate a new procedure for testing the equality of event rates in a design dividing each of k clusters into two segments having multiple sites (e.g., teeth, lesions). The test statistic proposed is a generalization of a previously published procedure based on adjusting the standard Pearson chi-square statistic, but can also be derived as a score test using the approach of generalized estimating equations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Allan Donner, Neil Klar, Guangyong Zou. 2004. Methods for the statistical analysis of binary data in split-cluster designs.. https://doi.org/10.1111/j.0006-341x.2004.00247.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of beta-sitosterol concentration and high pressure homogenization on the chlorhexidine release from vesicular gels.

Previous studies have confirmed that the phase transition of vesicular gels of hydrogenated phospholipids to the less ordered fluid vesicular state was induced by the increase of the beta-sitosterol ratio in the whole gel system and consequently in the lipid bilayer. The purpose of the present study was to evaluate the influence of the beta-sitosterol portion in the lipid bilayer and the effect of high pressure homogenization on the structural characteristics of the prepared gel systems. In addition the influence of beta-sitosterol on the consequent chlorhexidine release from the obtained vesicles and liposomes was also examined. Lipid mixtures were prepared from different molar ratios of lecithin:sterol components (90:10-65:35 mol%). The obtained mixtures were hydrated with the aqueous solution of chlorhexidine digluconate in order to achieve a 30% (w/w) final concentration of the lipid mixtures and a 4% (w/w) concentration of the drug. One portion of the resultant multilamellar vesicles was homogenized by using high pressure. To characterize the homogenized and non-homogenized systems, transmission electron microscopy of the freeze-fractured samples and differential scanning calorimetry (DSC) were carried out. A vertical type diffusion cell was applied to determine the amount of released chlorhexidine digluconate. Along with the increase in beta-sitosterol concentration, the fluidity of the membrane as well as its permeability also increased. The increased permeability--caused by the higher beta-sitosterol concentration--and the high pressure homogenization, which increased the dispersity and therefore the surface area, enabled a higher amount of chlorhexidine to be released. The increase of drug release was more pronounced in the case of samples prepared with high pressure homogenization.

Anti-Infective Agents, Local↗

The effectiveness of standard povidone iodine surgical preparation in decontaminating external fixator components.

The purpose of this study was to evaluate the effectiveness of standard iodine surgical scrubs to remove bacteria from external fixator components. Sterile adjustable external fixation clamps, Schanz pins, and carbon fibre rods were coated with a sterile protein solution and immersed in solution of coagulase negative Staphylococcus (10(3)organisms/ml). They were then decontaminated in standard fashion using a povidone iodine scrub and paint solution. After neutralisation the components were sonicated, serially diluted, plated on blood agar, and incubated for 24h. Unassembled external fixation components were examined individually, and as assembled pin-rod-clamp constructs with and without manipulation of the clamp. Of the three external fixation components (pins, rods, clamps) the highest number of bacterial colony forming units was seen on the external fixation clamps. Manipulation of the assembled construct significantly increased the mean bacterial colony counts compared to the assembled non-manipulated construct (p=0.0007). Standard surgical preparation does not remove all bacteria from external fixators during subsequent operative procedures.

Anti-Infective Agents, Local↗