PubMed Health⌕ Search

PubMed · 15641331

Sterilization update 2003.

Abstract

Instrument processing is a key part of the office infection control program. Each step in the process must be performed correctly to help ensure patient safety. The instrument processing area must be organized so that contaminated items are not confused with sterilized items, and so that sterilized items do not accidentally become recontaminated. Instruments need to be cleaned completely of visible debris using an ultrasonic cleaner or instrument washer. The cleaned instruments are packaged before sterilization to protect them from recontamination until they are opened for use for the next patient. Processing the packaged instruments through a heat sterilizer (steam, dry heat, or unsaturated chemical vapor) kills any microbes that remain on the instruments. The sterile packages are handled and stored in a manner that preserves the integrity of the packaging material. The use and functioning of the sterilizer is monitored by mechanical, chemical, and biological means, and records are kept to document these evaluations. Sterilization failures are addressed carefully so that patient safety can be maintained.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jennifer A Harte, Chris H Miller. 2004. Sterilization update 2003.. https://pubmed.ncbi.nlm.nih.gov/15641331/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison in vivo of the first tapered and nontapered instruments that bind at the apical constriction.

OBJECTIVE: To compare sizes of the first instrument with or without taper that binds to the narrow apical diameter of the root canal after coronal flaring. STUDY DESIGN: For the study, 388 canals were examined in patients with intact apices. A standard endodontic access cavity was prepared and the coronal third flared using standardized K-files, Gates Glidden reamers, or Profile rotary instruments. Apical patency was established using K-file size 10 and working length determined using an apex locator and radiographs. Standardized K-file hand instruments were gently introduced to working length beginning with size 15. The first K-file to bind to the canal walls and reach the working length was recorded as FKFB. Nontapered instruments (Lightspeed) were then gently introduced by hand to each canal in ascending order beginning with size 20 to working length. The first instrument to bind to the canal walls and reach the working length was recorded as FLSB. Statistical analysis was carried out using univariate analysis of variance. RESULTS: The average size of FLSB was approximately 2 ISO sizes larger than FKFB (P < .001). Minimal differences were found in the maxillary central incisors (6.7 +/- 3.0) and maximal differences in canals from maxillary lateral incisors (15.4 +/- 3.5). CONCLUSIONS: The first nontapered instruments to bind at the apical constriction were larger and reflected the actual narrow apical diameter of the canal better than the tapered instruments.

Dental Instruments↗

The ability of two apex locators to locate the apical foramen: an in vitro study.

The objective of this study was to compare the accuracy of the Root-ZX and Novapex electronic apex locators (EALs) in locating the apical foramen. Forty extracted human teeth were used. The coronal portion of each canal was flared using Gates Glidden drill. Canals were irrigated with 2.5% sodium hypochlorite. The actual length (AL) and electronic length (EL) measurements were made on each specimen separately with both devices with an aid of a K-type file. The results obtained with each EAL were compared with the corresponding control length. The statistical analysis of the results showed EAL reliability in detecting the apical foramen to 89.7% for the Root-ZX and 82.1% for the Novapex, taking the tolerance of +/-0.5 mm into account. A paired sample t test showed that there was no statistically significant difference between the accuracy of the devices (p = 0.4305). The results of this study indicate that the Root-ZX and Novapex are useful and accurate devices for the apical foramen location.

Dental Instruments↗

Determination of the minimum instrumentation size for penetration of irrigants to the apical third of root canal systems.

The purpose of this study was to determine the minimum instrumentation size required for the effective penetration of irrigants and elimination of debris and smear layer from the apical third of the root canals. The mesiobuccal canals of 40 freshly extracted human mandibular first molar teeth were instrumented using the crown-down technique. The teeth were divided into four test groups according to the size of their Master Apical File (#20, #25, #30, #35), and two control groups. After final irrigation, the removal of debris and smear layer from the apical third of root canals was determined under a scanning electron microscope. The data was analyzed using Kruskal-Wallis and Mann-Whitney tests. Based on the results, it appears that the minimum instrumentation size needed for penetration of irrigants to the apical third of the root canal is a #30 file.

Dental Instruments↗