PubMed Health⌕ Search

PubMed · 1564273

Electrophysiologic basis of dynamic extensor splinting.

Abstract

The use of dynamic extension splinting in the rehabilitation of extensor tendon injuries is gaining interest because of its apparent ability to improve clinical results. With such splinting, the extensor musculature is theoretically quiescent during both active flexion and rubber band-mediated extension; the gliding produced thereby decreases adhesion formation. Our initial intent was to perform electromyographic studies on volunteers in dynamic extension splinting to test this electrophysiologic principle. It was found, however, that only 16% of normal volunteers have quiescent extensor digitorum communis muscle activity within the dynamic extension splint typically used in this type of rehabilitation. A second splint was developed with a dorsal hood to keep the metacarpophalangeal joints in approximately 15 degrees of flexion. In this splint, 18 of 19 volunteers (95%) showed no extensor activity. The explanation for this phenomenon is not yet clear, but it shows that splint design plays a more significant role than previously expected. The expected electrophysiologic principle of dynamic extension splinting for extensor tendon injuries has been validated, but only in a splint design that is not commonly used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M L Newport, A Shukla. 1992. Electrophysiologic basis of dynamic extensor splinting.. https://doi.org/10.1016/0363-5023(92)90404-d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modulation operated by the sympathetic nervous system on jaw reflexes and masticatory movement.

The sympathetic nervous system (SNS), that is activated under condition of physical, psychological and psychosocial stress, affects force production and fatigability of muscles by controlling both muscle blood flow and the intracellular contractile mechanism. In addition SNS may affect motor function by modulating afferent activity from muscle spindles that are highly concentrated in jaw-closing muscles. Possible implications of these actions on masticatory function and myofascial pain are discussed.

Electromyography↗

Abnormal responses to repetitive transcranial magnetic stimulation in multiple system atrophy.

We studied the response of the motor cortex to brief trains of suprathreshold repetitive transcranial magnetic stimulations (rTMS) in patients with the Parkinson-variant of multiple system atrophy (MSA-P) and compared it to patients with idiopathic Parkinson's disease (PD) and healthy controls. Eight subjects were studied in each group, and patients were matched for disease severity as assessed by Hoehn & Yahr stages. rTMS was delivered at rest and during low-level contractions in trains of 10 stimulations at 5 Hz, and stimulation intensity was set to result in an motor evoked potential (MEP) in the first dorsal interosseus muscle of 0.5 to 1.0 mV. In MSA-P, MEP amplitude at rest was already reduced after the second stimulus and remained so, while it did not change in PD and controls. During contraction, MEP size did not change during the train in any group. The silent period that followed the last stimulus was of similar duration as the first stimulus in MSA-P, but was increased in PD and controls. These findings indicate that abnormal inhibition occurs within the motor cortex in MSA-P, despite dopaminergic treatment and indicate differences in cortical dysfunction between MSA-P and PD. We suggest that these abnormalities reflect the motor cortex pathology found in MSA-P.

Electromyography↗