PubMed Health⌕ Search

PubMed · 15715065

A tutorial on complex sound fields for audiometric testing.

Abstract

A fundamental understanding of soundfield characteristics in enclosed spaces is required in order to appreciate and predict the behavior of complex sound fields (i.e., sound fields created with at least two uncorrelated sound sources on different axes) used in auditory tests for evaluating hearing aid performance, especially speech-in-noise tasks. This article is a tutorial starting with idealized definitions of acoustical spaces. Next is an exploration of the interactions between practical sound fields and the enclosures that contain them, based on a synthesis of ideas formed from a review of classical acoustical theory combined with direct observation. Finally, the discussion turns to the application of complex sound fields for speech-in-noise testing in typical audiometric test rooms and a practical realization of such a sound field with consideration given to the limitations imposed by factors covered in the foregoing discussions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert M Ghent. 2005. A tutorial on complex sound fields for audiometric testing.. https://doi.org/10.3766/jaaa.16.1.3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Volitional control of attention and brain activation in dual task performance.

This study used functional MRI (fMRI) to examine the neural effects of willfully allocating one's attention to one of two ongoing tasks. In a dual task paradigm, participants were instructed to focus either on auditory sentence comprehension, mental rotation, or both. One of the major findings is that the distribution of brain activation was amenable to strategic control, such that the amount of activation per task was systematically related to the attention-dividing instructions. The activation in language processing regions was lower when attending to mental rotation than when attending to the sentences, and the activation in visuospatial processing regions was lower when attending to sentences than when attending to mental rotations. Additionally, the activation was found to be underadditive, with the dual-task condition eliciting less activation than the sum of the attend sentence and attend rotation conditions. We also observed a laterality shift across conditions within language-processing regions, with the attend sentence condition showing bilateral activation, while the dual task condition showed a left hemispheric dominance. This shift suggests multiple language-processing modes and may explain the underadditivity in activation observed in the current and previous studies.

Acoustic Stimulation↗

Frequency specific impairment of automatic pitch change detection by fMRI acoustic noise: an MEG study.

The loud acoustic noise produced by the magnetic resonance scanner is a major source of interference in auditory fMRI research. Whole-head magnetoencephalography (MEG) was used to investigate the interaction between the frequency range of auditory stimulation and fMRI acoustic noise. Pure tones and 3-harmonic complexes varying between 240 and 1240 Hz in frequency were presented while participants attended to a silent subtitled film. Continuous fMRI acoustic noise was presented during half of the blocks. The activity in six regions of interest was analyzed in 100-200 and 200-300 ms time windows to evaluate the magnetic counterparts of the mismatch negativity (MMN) and P3a brain responses. The results suggested that fMRI noise significantly reduced the amplitude of these responses. The effect of the noise on the automatic processing of the tones was more prominent for the tones with frequencies higher than 500 Hz. It is recommended that in the MMN protocols using continuous fMRI acquisition the sound stimuli should be spectrally separated from the fMRI scanner noise spectrum.

Acoustic Stimulation↗

Protective properties of idebenone in noise-induced hearing loss in the guinea pig.

Idebenone is a synthetic analogue of coenzyme Q10 with antioxidant properties. The present study investigated the antioxidant activity of idebenone in the rescue of acoustic trauma. Noise-induced hearing loss was induced by exposing guinea pigs to a continuous pure tone and idebenone was injected intraperitoneally 1 h before noise exposure and once daily for 3 days. Guinea pigs treated with idebenone showed significantly smaller auditory threshold shifts than unprotected control animals. Missing and apoptotic cells were identified with scanning electron microscopy and terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling assay. Protected animals presented a lesser extent of both apoptotic activation and hair cell loss in the organ of Corti. Our results suggest an antioxidant function of idebenone in protection from noise-induced hearing loss and provide a rationale for exploring therapeutic strategies in humans.

Acoustic Stimulation↗