An optimal reference plane to detect glaucomatous nerve fiber layer abnormalities with computerized image analysis.

Abstract

Nerve fiber layer height measured with respect to a standardized retinal reference plane is diminished by glaucoma. The definition of the reference plane influences the nerve fiber layer measurements. We empirically determined the best reference plane for measurement of nerve fiber layer height. Optimal parameters for measurement reproducibility were determined for a group of 6 normal and 6 glaucomatous eyes each imaged nine times. Optimal ability to distinguish normal from glaucomatous eyes was determined for a group of 33 normal eyes and 36 glaucomatous eyes each imaged once. Measurements with the smallest variability (root mean square error = 32 microns) and the highest sensitivity (83%) and specificity (88%) were achieved when the reference plane is defined by portions of the image from a peripheral temporal area 32 degrees wide, and for two peripheral nasal areas of 55 degrees width centered 30 degrees above and below horizontal. These parameters for the definition of the reference plane should provide measurements of nerve fiber layer height with the least variability and the greatest ability to discriminate between eyes with early glaucomatous damage and normal eyes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Miller, J Caprioli. 1992. An optimal reference plane to detect glaucomatous nerve fiber layer abnormalities with computerized image analysis.. https://doi.org/10.1007/bf00164649

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗