Risk curve boundaries.

Abstract

Insights into the science and the dynamics associated with the stimulus-injury relationship of the human system are often gained by focusing on the results obtained from human surrogate testing. These results are commonly mapped into an injury risk paradigm for the purpose of characterizing the stimulus injury response: the injury risk curve. However, the quality and quantity of the data along with the experimental design are critical factors when considering the value of the estimated risk curve. Presented in this article is an analysis of injury risk curves in terms of their usability and appropriateness with respect to the sample size, stimulus distribution over the critical range, censoring, shape of the underlying risk function, and the inclusion of "actual" (uncensored) along with censored data. The results from this analysis indicate that for "large" biomechanical injury data sets there is no advantage to using actual data; censored data will yield the same injury risk curve as actual data. However, for "small" biomechanical injury data sets the inclusion of actual data will significantly improve the quality of the resulting risk curve. In addition, the results show that the amount of injury data needed to generate a risk curve with a given confidence bound is not only dependent on the relative contribution of the censored data and actual data but also on the shape of the risk function along with the stimulus distribution over the critical range. Confidence intervals are presented for the thoracic injury risk and the head injury risk to show the influence of data distribution on the goodness of the risk function estimation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Di Domenico, G Nusholtz. 2005. Risk curve boundaries.. https://doi.org/10.1080/15389580590903212

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗