Bone-like polyethelyne burr-hole cover.

Abstract

OBJECTIVE: Several materials are available for covering burr holes but none of them are ideal with respect to biocompatibility, strength and morbidity. With these properties in mind, our objective was to design a porous polyethylene device, which looked like bone and provides protection and cosmesis while being quick and easy to apply. METHODS AND MATERIALS/RESULTS: A burr-hole cover was created to cover small cranial defects and craniostomies. Using high-density polyethylene, this cover was designed to resemble the bony structure of the skull. Its porous architecture allows for tissue ingrowth and bony integration. It consists of a cylinder which fits into the burr hole and a cap which can be sutured or anchored with titanium screws. CONCLUSIONS: The "bone-like" burr-hole cover provides adequate protection, biocompatibility and cosmesis and is simple to use. Alternative implants can be toxic to surrounding tissues, costly and time consuming to apply. This high-density polyethylene cover is compatible with surrounding tissue as well as being of a porous nature and the material it is made from offers high tensile strength for adequate protection.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Manuel Dujovny, Alberto Aviles, Pedro Cuevas. 2005. Bone-like polyethelyne burr-hole cover.. https://doi.org/10.1179/016164105x22138

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of Runx2 genetic engineering and in vitro maturation of tissue-engineered constructs on the repair of critical size bone defects.

Genetic and tissue engineering strategies are being pursued to address the clinical limitations of current bone grafting materials. Based on our previous work demonstrating that overexpression of the Runx2 osteoblastic transcription factor and in vitro construct maturation synergistically enhanced in vivo mineralization in an ectopic site (Byers et al., Tissue Eng 2004;10:1757-1766), we examined the effects of these two parameters on the repair of critical size bone defects. Primary rat bone marrow stromal cells transduced with Runx2 or control (no Runx2 insert) retroviral vector were seeded onto 3D fused deposition-modeled polycaprolactone scaffolds. Runx2-modified cells produced biologically-equivalent mineralized matrices at nearly 2-fold higher rates than control cells. Constructs cultured in vitro for 1 day (immature) or 21 days (mineralized) were subsequently implanted into critical size calvaria defects in syngeneic rats, and bone healing was analyzed by micro-CT and histomorphometry at 28 days. Runx2-modified and control constructs precultured for 1 day healed to a greater extent than defects receiving no implant. Cell-free scaffolds yielded equivalent levels of bone formation as constructs precultured for 1 day. Interestingly, defects treated with control cell-seeded constructs precultured for 21 days exhibited low bone formation compared to other construct treatments, and repair was comparable to empty defects. In contrast, Runx2-modified constructs precultured for 21 days contained twice as much bone as control constructs precultured for 21 days and equivalent levels of new bone as cell-free and 1 day precultured constructs. These results demonstrate interplay between Runx2 genetically-modified cells and in vitro construct maturation in bone healing responses.

Absorbable Implants↗

Resorbable poly(D,L)lactide plates and screws for osteosynthesis of condylar neck fractures in sheep.

We made osteotomies in the condylar neck in 12 adult sheep to simulate fractures, and joined the two ends with 2 poly(D,L)lactide (PDLLA) plates and 8 PDLLA screws 2mm in diameter. The animals were killed after 2, 6, and 12 months and bony healing was assessed macroscopically and histologically. The plates and screws remained intact and there was no displacement of the bony ends. The degrading plates, which were still visible in the specimens after 6 months, had been replaced by bone. At 12 months the PDLLA had been resorbed with no foreign body reaction and no resorption of underlying bone. The articular discs showed no signs of degeneration.

Absorbable Implants↗

Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction.

Poly-L: -lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29-year-old female patient with a failure of a biodegradable interference screw at 22 months after ACL reconstruction using bone-patellar tendon-bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990-2005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.

Absorbable Implants↗