Eighty-four consecutive breast reconstructions using a textured silicone tissue expander.

Abstract

Breast reconstruction utilizing smooth-surface silicone tissue expanders is associated with certain problems. Significant capsular contracture may develop around the expander with subsequent expander displacement necessitating repositioning or capsulectomy at the time of expander removal. Infection, pain on expansion, chest-wall compression, and complications related to the remote fill valve also have been reported. A textured-surface silicone expander with an integrated fill valve was developed to address these issues. Eighty-four consecutive breast reconstructions were performed by a single surgeon using textured expanders in 55 patients. Intraexpander pressures were measured during expansion for a group of these patients, and both initial and postinflation pressure readings were quite low (average initial pressure 2.88 mmHg; average postinflation pressure 12.87 mmHg). Eighty-one of the reconstructions have been completed without any expander losses and with minimal complications. Tissue expander volume averaged 580 cc, and the expansion duration averaged 5.6 months. Various types and configurations of permanent implants were used to complete the reconstructions. Eighty-four percent of our patients' completed reconstructions (including nippleareola reconstruction and opposite breast alteration, when necessary) were accomplished with just two procedures. Seventeen long-term adjustable textured-surface expander/implants with anatomic breast shape are still in place, all after only one operation. The inframmary fold has generally been established passively by the expansion process alone. Textured-surface silicone expanders have stayed where positioned, have expanded easily with minimal patient pain, and have created a noncontractile soft-tissue cover for the final implant. The textured expander with an integrated fill valve has simplified breast reconstruction by helping to limit the problems encountered with smooth silicone expanders. The resulting reconstructions have remained soft with a very acceptable aesthetic appearance. The patient office and hospital charts and photographs of this consecutive series were notarized and submitted to the Editor of this Journal, whose biostatistician randomly selected the cases illustrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G P Maxwell, P A Falcone. 1992. Eighty-four consecutive breast reconstructions using a textured silicone tissue expander.. https://pubmed.ncbi.nlm.nih.gov/1584864/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗