PubMed Health⌕ Search

PubMed · 15915256

An electrochemically driven poly(dimethylsiloxane) microfluidic actuator: oxygen sensing and programmable flows and pH gradients.

Abstract

We describe the fabrication and performance of an integrated microelectrochemical reactor-a design possessing utility for multiple applications that include electrochemical sensing, the generation and manipulation of in-channel microfluidic pH gradients, and fluid actuation and flow. The device architecture is based on a three-electrode electrochemical cell design that incorporates a Pt interdigitated array (IDA) working (WE), a Pt counter (CE), and Ag pseudo-reference (RE) electrodes within a microfluidic network in which the WE is fully immersed in a liquid electrolyte confined in the channels. The microchannels are made from a conventional poly(dimethylsiloxane)(PDMS) elastomer, which serves also as a thin gas-permeable membrane through which gaseous reactants in the external ambient environment are supplied to the working electrode by diffusion. Due to the high permeability of oxygen through PDMS, the microfluidic cell supports significantly (>order of magnitude) higher current densities in the oxygen reduction reaction (ORR) than those measured in conventional (quiescent) electrochemical cells for the same electrode areas. We demonstrate in this work that, when operated at constant potential under mass transport control, the device can be utilized as a membrane-covered oxygen sensor, the response of which can be tuned by varying the thickness of the PDMS membrane. Depending on the experimental conditions under which the electrochemical ORR is performed, the data establish that the device can be operated as both a programmable pH gradient generator and a microfluidic pump.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Svetlana M Mitrovski, Ralph G Nuzzo. 2005-05-09. An electrochemically driven poly(dimethylsiloxane) microfluidic actuator: oxygen sensing and programmable flows and pH gradients.. https://doi.org/10.1039/b416671j

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surface treatment on diffusion and domain formation in supported lipid bilayers.

Supported lipid bilayers are widely used as model systems due to their robustness. Due to the solid support, the properties of supported lipid bilayers are different from those of freestanding bilayers. In this article, we examine whether different surface treatments affect the properties of supported lipid bilayers. It will be shown that depending on the treatment method, the diffusion of the lipids can be adjusted approximately threefold without altering the composition. Additionally, as the bilayer-support interaction decreases, it becomes easier to form coexisting liquid-ordered and liquid-disordered domains. The physical/chemical alterations that result from the different treatment methods will be discussed.

Diffusion↗

An early example of evidence-based medicine: hypoxemia due to nitrous oxide.

Diffusion anoxia. By Bernard Raymond Fink. Anesthesiology 1955; 16:511-14. In 1955, Dr. Bernard Raymond Fink published his findings that described the mechanism by which hypoxemia occurred when nitrous oxide-oxygen anesthesia was discontinued and room air breathing commenced. Using an ear oximeter and brachial artery blood gases, he measured oxygen saturation in eight healthy patients who had received 75% nitrous oxide-25% oxygen for gynecologic surgery. He showed that oxygen saturation decreased from 5% to 10% and often reached a value below 90% when the patient began room air breathing after the nitrous oxide-oxygen was discontinued. The effect was seen over a 10-min period. He concluded that "anoxia arises because the outward diffusion of nitrous oxide lowers the alveolar partial pressure of oxygen." This phenomenon can become a causative factor of cardiac arrest in patients with impaired pulmonary or cardiac reserves.

Diffusion↗