PubMed Health⌕ Search

PubMed · 15975333

High flow rates during modified ultrafiltration decrease cerebral blood flow velocity and venous oxygen saturation in infants.

Abstract

BACKGROUND: The intracranial hemodynamic effects of modified ultrafiltration in children are unknown. We investigated the effects of different blood flow rates during modified ultrafiltration on the cerebral hemodynamics of children with weights above and below 10 kg. METHODS: Thirty-one children (weights: < or = 10 kg, n = 21; > 10 kg, n = 10) undergoing cardiopulmonary bypass were studied. Middle-cerebral artery blood flow velocities and cerebral mixed venous oxygen saturations were measured before, five minutes from the beginning, and at the end of ultrafiltration. Patients were classified according to their blood flow rates during ultrafiltration in three groups: high (> or = 20 mL/kg/min), moderate (10-19 mL/kg/min), and low flow rates (< 10 mL/kg/min). RESULTS: During modified ultrafiltration, blood pressures and hematocrit increased (p < 0.001), but cerebral blood flow velocities and mixed venous oxygen saturations decreased (p < 0.001). A significant correlation was found between blood flow rates of ultrafiltration and the decline in mean cerebral blood flow velocity (r = - 0.48; p = 0.005) and cerebral oxygen saturation (r = - 0.49; p = 0.005) or hematocrit increase (r = 0.59; p = 0.001). Infants exposed to high flow rates had greater reduction of cerebral blood flow velocity and regional mixed venous saturation and higher hematocrit at the end of ultrafiltration compared with those subjected to moderate and low flow rates (p < 0.04). No significant difference was found between moderate and low flow groups. The flow rate of ultrafiltration was the only independent predictor of the changes in cerebral mixed venous oxygen saturation (p = 0.033). CONCLUSIONS: High blood flow rates through the ultrafilter during modified ultrafiltration transiently decrease the cerebral circulation in young infants compared with lower blood flow rates. These effects may be related to an increased diastolic runoff from the aorta into the ultrafiltration circuit that leads to a "stealing" effect from the intracranial circulation, which may be important in infants with dysfunctional cerebral autoregulation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rosendo A Rodriguez, Marc Ruel, Lothar Broecker, Garry Cornel. 2005. High flow rates during modified ultrafiltration decrease cerebral blood flow velocity and venous oxygen saturation in infants.. https://doi.org/10.1016/j.athoracsur.2005.01.030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Vascular bed origin dictates flow pattern regulation of endothelial adhesion molecule expression.

Endothelial cell phenotypes markedly differ, depending upon function and vascular bed of origin. Differences might account for specific susceptibility to pathological conditions. As leukocyte adhesion to activated endothelium is the initiating event in a range of diseases, we compared the influence of vascular bed-specific flow patterns on adhesion molecule expression in human saphenous vein (HSVEC) and coronary artery endothelial cells (HCAEC). In vitro, immune cell attachment was increased 1.6-fold when tumor necrosis factor (TNF)-alpha-stimulated HSVEC were exposed to coronary artery flow in place of physiological venous flow and 1.9-fold higher compared with attachment to cytokine-stimulated HCAEC exposed to coronary artery flow. This was associated with increased concentrations of soluble E-selectin, VCAM-1, and ICAM-1 in supernatants of HSVEC exposed to coronary artery flow compared with HCAEC exposed to the same flow pattern. Venous and coronary artery flow both increased TNF-alpha-induced E-selectin and ICAM-1 expression on HSVEC, but only coronary artery flow increased VCAM-1 expression. In marked contrast to HSVEC, venous and coronary artery flow attenuated TNF-alpha-induced E-selectin and VCAM-1 expression on HCAEC, whereas coronary artery flow further induced ICAM-1 on cytokine-stimulated HCAEC. With the exception of cytokine-induced ICAM-1, adhesion molecule expression on HSVEC exposed to coronary artery flow exceeded expression on HCAEC. Thus ICAM-1 expression involves complex flow-dependent and -independent pathways with marked dissimilarities between the two endothelial cell types studied. Interestingly, Kruppel-like factor (KLF) 4 overexpression in HCAEC and HSVEC significantly reduced TNF-alpha-induced E-selectin and VCAM-1 expression in static conditions, while ICAM-1 expression remained constant. Furthermore, both flow patterns induced KLF2 and KLF4 expression in HCAEC and HSVEC. Venous and coronary artery flow differentially influence endothelial adhesion molecule and transcription factor expression, depending on the vascular bed of origin. Differences in adhesion molecule expression and subsequent immune cell adhesion between HSVEC and HCAEC may contribute to different susceptibility to pathological conditions.

Blood Flow Velocity↗

Mesoscale simulation of blood flow in small vessels.

Computational modeling of blood flow in microvessels with internal diameter 20-500 microm is a major challenge. It is because blood in such vessels behaves as a multiphase suspension of deformable particles. A continuum model of blood is not adequate if the motion of individual red blood cells in the suspension is of interest. At the same time, multiple cells, often a few thousands in number, must also be considered to account for cell-cell hydrodynamic interaction. Moreover, the red blood cells (RBCs) are highly deformable. Deformation of the cells must also be considered in the model, as it is a major determinant of many physiologically significant phenomena, such as formation of a cell-free layer, and the Fahraeus-Lindqvist effect. In this article, we present two-dimensional computational simulation of blood flow in vessels of size 20-300 microm at discharge hematocrit of 10-60%, taking into consideration the particulate nature of blood and cell deformation. The numerical model is based on the immersed boundary method, and the red blood cells are modeled as liquid capsules. A large RBC population comprising of as many as 2500 cells are simulated. Migration of the cells normal to the wall of the vessel and the formation of the cell-free layer are studied. Results on the trajectory and velocity traces of the RBCs, and their fluctuations are presented. Also presented are the results on the plug-flow velocity profile of blood, the apparent viscosity, and the Fahraeus-Lindqvist effect. The numerical results also allow us to investigate the variation of apparent blood viscosity along the cross-section of a vessel. The computational results are compared with the experimental results. To the best of our knowledge, this article presents the first simulation to simultaneously consider a large ensemble of red blood cells and the cell deformation.

Blood Flow Velocity↗

Doppler sonography evaluation of flow velocity and volume of the extracranial internal carotid and vertebral arteries in healthy adults.

PURPOSE: To measure with Doppler sonography the velocity and volume of blood flow in the extracranial internal carotid artery (ICA) and vertebral artery (VA) of healthy adults and to calculate total cerebral blood flow volume (tCBFV). METHODS: Bilateral ICA and VA were examined sonographically in 180 healthy adults. Angle-corrected peak systolic (Vps), end-diastolic (Ved), and time-averaged maximum blood flow velocity (TAV) were measured in pulsed Doppler mode, and the resistance index (RI) and pulsatility index (PI) were calculated. The cross-sectional area (A) was measured on gray-scale images. Volume flow was calculated as FV = TAV x A, and tCBFV was calculated as the sum of the right and left ICA and VA volume flow. RESULTS: tCBFV was 651 +/- 96 ml/min for the entire population. There was a significant decrease in Vps, Ved, TAV, and tCBFV with age in all arteries. RI and PI values initially declined and then increased with age. Cross-sectional area increased with age in ICA but not in VA. PI and RI were higher in men than in women. Blood flow velocity and volume were higher, and RI was lower in the left than in the right VA. CONCLUSION: The Doppler sonographic assessment of extracranial ICA and VA blood flow volume may be useful for the study of cerebral hemodynamic changes in patients with cerebrovascular disorders. Age-dependent changes should be considered, for instance, in the management of intensive care patients with impaired cerebral perfusion.

Blood Flow Velocity↗