PubMed Health⌕ Search

PubMed · 16112807

Water mapping in hydrated soft materials.

Abstract

We present a method based on spatially resolved electron energy-loss spectroscopy in the cryo-STEM to map the spatial distribution of water in frozen-hydrated polymers. The spatial resolution is limited by the dose constraints imposed by radiation damage, and to stay within these constraints, the use of fine electron-probe sizes comes at the cost of reduced counts in the energy-loss spectra. Thus, at the resolution limit, the detection of isolated water-rich pixels or the identification of minor variations in water content across the specimen is complicated because one must distinguish significant fluctuations from noise. Here we develop a criterion with which to guide such a distinction. We characterize the intrinsic noise associated with spectral measurements under given illumination and acquisition conditions. We then use that noise in combination with scatter diagrams to threshold spectrum images and objectively identify statistically significant compositional fluctuations. We illustrate these ideas using a simulated spectrum dataset for a hypothetical blend of hydrophilic and hydrophobic homopolymers. We show that while a direct inspection of the water map may not allow any meaningful conclusions to be drawn, after applying the thresholding approach we can clearly identify the regions of the specimen that are rich in water. We also experimentally study a model blend system comprised of hydrophilic poly(vinyl pyrrolidone) (PVP) dispersed in a hydrophobic matrix of poly(styrene) (PS). By MLS fitting using damaged and undamaged PVP reference spectra, we determine that the critical dose characteristic of dry PVP is approximately 8000 e/nm2 using 200 keV incident electrons. Irradiating frozen-hydrated PVP gives rise to noticeable hydrogen evolution at doses of approximately 1500 e/nm2. To stay within this constraint we use doses of 400 e/nm2 and a pixel spacing in the spectrum imaging of 100 nm. In order to quantitatively map the water, PVP, and PS compositions, we measure their total inelastic scattering cross-sections. Direct inspection of the composition maps reveals the presence of large water-rich domains of the order of approximately 1 microm and the scatter-diagram thresholding approach identifies small water-rich domains one pixel in size.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alioscka Sousa, Abdelaziz Aitouchen, Matthew Libera. 2005-07-28. Water mapping in hydrated soft materials.. https://doi.org/10.1016/j.ultramic.2005.06.059

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Four years experience with teleneuropathology.

Between 2002 and 2005, we made 343 intraoperative frozen section diagnoses with a telepathology system, which connected a neurosurgical department to our department of pathology. An expert neuropathologist performed at least one brief gross examination, and this was followed by a smear preparation and a frozen section slide for each case. Frozen section diagnosis lasted on average 26.1 min, calculated from the beginning of gross examination until the surgeon was given the diagnosis. The majority of cases (283 or 83%) were diagnosed in 15-40 min. The mean time needed for macroscopic examination was 3.0 min, time for staining 4.2 min, smear diagnosis took 5.4 min and time for histological diagnosis 10.7 min. Telemicroscopy of a smear slide took 11 times longer compared with light microscopy, and telemicroscopy of a frozen section slide took 16 times longer than with light microscopy. In 6% of cases, the telepathology software posed technical problems, which delayed the time of diagnosis, but not by more than 4 min. We were able to render a diagnosis in all cases (system reliability 100%). After eliminating sampling errors (i.e. cases with no diagnostic material in the frozen section slides and/or in smear preparations), the diagnostic accuracy for telepathology was 97.9%.

Frozen Sections↗