Contaminated Irrigasol solution.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M R Nair. 1999. Contaminated Irrigasol solution.. https://pubmed.ncbi.nlm.nih.gov/16130289/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Preparation of 99mTc-MAG3: radiochemical purity is affected by the residence time of sodium chloride injection in a three-part syringe.

BACKGROUND: Routine technetium-99m mercaptoacetyltriglycine (99mTc-MAG3) radiochemical purity measurements have revealed occasional unacceptably low values. Preliminary investigations suggested a causal link with the residence time of sodium chloride injection in the syringe used to reconstitute the MAG3 kit. OBJECTIVES: To investigate the cause of this phenomenon, determine how it can be avoided and establish whether it occurs with other 99mTc radiopharmaceuticals. METHODS: 99mTc-MAG3 was prepared by drawing sodium chloride injection into a lubricated, three-part, 10 ml Plastipak syringe and using it to reconstitute a MAG3 kit immediately or after a 15 min incubation period. The radiochemical purity was measured by high-performance liquid chromatography. The experiment was repeated using lubricant-free, two-part, Norm-Ject syringes and lubricated, two-part, Monoject syringes (15 min incubation only). To investigate the influence of Plastipak's rubber components on the radiochemical purity, samples were prepared using sodium chloride injection that had been incubated with lubricated or lubricant-free rubber plunger ends. Similar experiments were performed to determine the effect of Plastipak on 99mTc-exametazime, 99mTc-sestamibi and 99mTc-tetrofosmin. RESULTS: The radiochemical purities of 99mTc-MAG3 prepared with sodium chloride injection incubated for 0 and 15 min in Plastipak syringes were 96.4+/-0.5% and 89.4+/-5.5%, respectively. The difference was significant (P<0.05, n=10). With Norm-Ject syringes, the radiochemical purities were 96.5+/-0.5% and 96.6+/-0.5%, respectively. The difference was not significant (P>0.05, n=10). With Monoject syringes, the radiochemical purity was 96.6+/-0.4% (n=10). 99mTc-MAG3 prepared using sodium chloride injection treated with lubricated and unlubricated syringe rubber plunger ends had radiochemical purities of 85.3+/-6.6% and 82.1+/-6.5% (n=5), respectively. The radiochemical purities of other 99mTc radiopharmaceuticals prepared using sodium chloride injection incubated for 0 or 15 min in Plastipak syringes were as follows: 99mTc-exametazime, 95.3+/-0.6% and 94.5+/-1.8%; 99mTc-sestamibi, 98.0+/-0.6% and 97.7+/-0.6%; 99mTc-tetrofosmin, 96.5+/-0.2% and 97.0+/-0.4%. None of the differences was significant (P>0.05, n=5). CONCLUSIONS: A lipophilic impurity, originating from the rubber plunger of a three-part Plastipak syringe, is formed in 99mTc-MAG3 when the sodium chloride injection used to reconstitute the kit is in the syringe for a prolonged time. The effect is eliminated by using a two-part syringe or by injecting the sodium chloride injection into the kit immediately. The phenomenon does not occur with 99mTc-exametazime, 99mTc-sestamibi or 99mTc-tetrofosmin.

Drug Contamination↗

Pharmacological content of tablets sold as "ecstasy": results from an online testing service.

PURPOSE: This study examined the pharmacological content of tablets sold as ecstasy, the variation of tablet content by geographic region, and change in tablet content between 1999 and 2005. METHODS: The sample was comprised of tablets anonymously submitted for laboratory testing between 1999 and 2005 (n=1214). Tablet height, width, geographic region, and year of submission were all used to predict the pharmacological content of the tablets. RESULTS: Overall, 39% of the tablets were comprised of MDMA only, 46% only contained substances other than MDMA and 15% were mixtures of MDMA and other substances. Tablet height and width were inversely related to tablet purity. Ecstasy tablets from California and Florida had decreased likelihoods of containing non-MDMA substances. The purity of tablets decreased over time, which was largely a result of an increasing number of tablets comprised of MDMA along with other substances. CONCLUSIONS: Ecstasy users may be putting themselves at increased risk of substance-induced anxiety, mood, and psychotic disorders by unknowingly ingesting substances other than MDMA. To decrease detrimental health effects, prevention programs should emphasize the impurity of ecstasy tablets and focus on the health impacts of these substances, particularly for populations at high-risk of substance-induced disorders.

Drug Contamination↗

Radioactive byproducts in [18O]H2O used to produce 18F for [18F]FDG synthesis.

Potential radioactive byproducts in [(18)O]H(2)O irradiated with 9.6 MeV protons to produce (18)F were analyzed theoretically and experimentally. Twenty two nuclear reaction cross sections included in the National Nuclear Data Center's (NNDC) data base were selected from the possible nuclear reactions between 9.6 MeV protons and a silver havar target. Ten radionuclides: (52)Mn, (55)Fe, (55)Co, (56)Co, (57)Co, (58)Co, (59)Ni, (95)Tc, (96)Tc and (109)Cd were detected experimentally in [(18)O]H(2)O by using high purity germanium semiconductor detectors. The activities of the 10 radionuclides were distributed between 4B q and 1.2k Bq. These activities were less than the reference values given in the International Basic Safety Standards. The radionuclides derived from nuclear reactions between a silver target body and 9.6 MeV protons at a beam current 25 microA for 60 min irradiation would be exempt from restrictions for radioactive waste. The purified [(18)F]FDG prepared from (18)F produced by irradiating a silver havlar target with 9.6 MeV protons was not contaminated by the radionuclides.

Drug Contamination↗