PubMed Health⌕ Search

PubMed · 1613240

Comparative flexor tendon excursion after passive mobilization: an in vitro study.

Abstract

Two experimental studies were conducted to investigate flexor tendon excursions. In the first study, tendon excursions due to passive joint motion in various loading condition were evaluated. In the second study, the efficacy of a new technique that used synergistic wrist motion (S-splint) was compared with the traditional dorsal splinting methods: the Kleinert splint (K-splint) and the Brooke Army Hospital/Walter Reed modified Kleinert splint with a palmar bar (P-splint). The results of these studies question the anticipated tendon excursion associated with postoperative splinting. They demonstrated that the measured tendon excursion under a condition of low tendon tension was almost half that of theoretically predicted values. In zone II, the magnitude of excursion introduced by the three mobilization methods were in descending order: S-splint, P-splint, K-splint (p less than 0.05). Differential tendon excursion between the flexor digitorum profundus and the flexor digitorum superficialis had a mean value of 3 mm and was not significantly different among the three methods. Passive proximal interphalangeal joint motion was the most effective means of providing increased amplitude of tendon gliding in zone II. Passive distal interphalangeal joint motion did not increase excursion in zone II as much as had been predicted.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Horii, G T Lin, W P Cooney, R L Linscheid, K N An. 1992. Comparative flexor tendon excursion after passive mobilization: an in vitro study.. https://doi.org/10.1016/0363-5023(92)90371-u

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A population-based study of cancer incidence in solid organ transplants from donors at various risk of neoplasia.

A population-based cohort study of recipients of organs from donors with a recognized history or active cancer has been conducted by linking the Italian National Registry of Transplanted Patients and the National Registry of Donors with Neoplasia Risk. Between 2002 and 2004, 8,198 solid organ transplants have been performed in Italy, 108 of them with organs from 59 cadaveric donors with various risk of neoplasia. There were two reported cases of nonmelanoma skin cancer during the follow up of the transplanted patients, which lasted 27.6+/-11.3 months (234 patient-years). In our study, recipients of organs from donors with various degree of neoplasia risk are exposed to a low risk of cancer transmission.

Cadaver↗

[Primary stability of the capsule-labrum complex after reconstruction with the Mitek Bioknotless anchor system in human cadaver models].

BACKGROUND: This study examines the postoperative stability of the Mitek Bioknotless anchor system with biomechanical draw-out pulling in human cadaver shoulders. METHOD: With simulation of anterior shoulder dislocation a test group (n=10, Ø 45 years) was tested against a native group (n=8, Ø 47 years). All shoulders were dissected up to the passive stabilizers. In the test group an artificial Bankart lesion was created and repaired with three Mitek Bioknotless anchors. The humeri of both groups were fixed in 60 degrees glenohumeral abduction and 90 degrees external rotation and then dislocated in a ventral direction. For evaluation purposes the ultimate draw-out strength, mode of failure, translation of humeral head, capsular slope, and bone density in the test group were measured. RESULTS: In the test group the ultimate strength was a median of 937 N (min. 554 N, max. 1,294 N) with 28 bony anchor dislocations, 1 suture rupture, and 1 capsular rupture, and in the native group with 6 Bankart and 2 HAGL lesions it was 1,214 N (708 N, 1,471 N). The bone density showed a positive correlation to the draw-out strength regarding cortical density and total density. CONCLUSION: Regarding the high draw-out strength the Mitek Bioknotless anchor system provides enough stability for early functional treatment.

Cadaver↗