Abstract

RATIONALE AND OBJECTIVES: There is a need to provide real-time dosimetric feedback during prostate brachytherapy based on the location of the implanted seeds. The objective of our approach is to develop a system to accurately locate seeds with minimal impact on the current protocol for prostate brachytherapy and without additional imaging equipment. MATERIALS AND METHODS: A new approach for intraoperatively computing dosimetry for prostate brachytherapy is presented. The approach uses transrectal ultrasound (TRUS) and fluoroscopic images. A fluoroscopic image of the TRUS probe is required to register the fluoroscopic and ultrasound images. The C-arm is not moved during the procedure and all images are acquired from the same C-arm angles. A needle path is interpolated for each needle based on the location of the needle tip in TRUS images and the known entry point of the needle. Throughout the procedure, fluoroscopic images are acquired to determine the coronal plane coordinates of the seeds and the remaining coordinate of each seed is computed from the needle path. For accurate results, intraoperative seed motion tracking is advised and a method to achieve such tracking is also presented. RESULTS: Experimentally, the TRUS and fluoroscopic images are registered with a mean and maximum error of 1.3 mm and 5.8 mm, respectively. In a phantom, 12 seeds are located using our approach and compared with the known locations, with a mean error in the x, y, and z direction of 0.96 mm, 0.33, and 0.68 mm, respectively, and a corresponding maximum error of 1.85 mm, 0.56 mm, and 1.63 mm. Experimental results show motion tracking in the y-direction with submillimeter accuracy. The feasibility of our approach is tested on five cases of clinical data using a semiautomated version of our system and the resulting dosimetry is compared with that found using postoperative computed tomography images. The D90 and V100 metrics computed using our approach and the computed tomography images differ by a maximum of 16.6% and 1.7%, respectively. CONCLUSIONS: TRUS can be combined with single pose fluoroscopic images to compute delivered dose intraoperatively for prostate brachytherapy. Phantom results demonstrate the accuracy of the method and preliminary clinical results show its potential.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Danny French, James Morris, Mira Keyes, Orcun Goksel, Septimiu Salcudean. 2005. Computing intraoperative dosimetry for prostate brachytherapy using TRUS and fluoroscopy.. https://doi.org/10.1016/j.acra.2005.05.026

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

CT-based postimplant dosimetry of prostate brachytherapy: comparison of 1-mm and 5-mm section CT.

PURPOSE: The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. MATERIALS AND METHODS: A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V(100) (percent of the prostate volume receiving at least the full prescribed dose), and prostate D(90) (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. RESULTS: The mean +/-1 SD postimplant pVol was 20.17 +/- 6.66 cc by 1-mm section CT and 22.24 +/- 8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P < 0.01). The mean postimplant prostate V(100) was 80.44% +/- 7.06% by 1-mm section CT and 77.33% +/- 10.22% by 5-mm section CT. The mean postimplant prostate D(90) was 83.28% +/- 10.81% by 1-mm section CT and 78.60% +/- 15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. CONCLUSION: Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility.

Brachytherapy↗

Long-term results of breast cancer irradiation treatment with low-dose-rate external irradiation.

PURPOSE: The aim of this study was to assess beam therapy with low-dose-rate (LDR) external irradiation in a group of patients with breast cancer. METHODS AND MATERIALS: This trial compared, from 1986 to 1989, patients with advanced breast cancer treated either by conventional fractionation or low-dose-rate (LDR) external radiotherapy (dose-rate 15 mGy/min, 5 sessions of 9 Gy delivered on 5 consecutive days). RESULTS: A total of 21 patients were included in the fractionated therapy arm. At follow-up 15 years after treatment, 7 local recurrences had occurred, 3 patients had died of cancer, 18 patients were alive, 10 were without evidence of disease, and 6 had evidence of disease. A total of 22 patients had been included in the LDR arm of the study. Of these, 11 had received a dose of 45 Gy; thereafter, in view of severe local reactions, the dose was reduced to 35 Gy. There was no local recurrence in patients who had received 45 Gy, although there were 2 local recurrences among the 11 patients after 35 Gy. The sequelae were severe in patients who received 45 Gy but were comparable to those observed in patients treated by fractionated radiotherapy who received 35 Gy. The higher efficacy of tumor control in patients treated by LDR irradiation as well as the lower tolerance of normal tissue are probably related to the lack of repopulation. CONCLUSION: Although the patient numbers in this study are limited, based on our study results we conclude that the data for LDR irradiation are encouraging and that further investigation is warranted.

Brachytherapy↗

Five-year outcome of intraoperative conformal permanent I-125 interstitial implantation for patients with clinically localized prostate cancer.

PURPOSE: To report the 5-year tumor control and toxicity outcomes for patients with localized prostate treated with I-125 permanent implantation using an intraoperative real-time conformal planning technique. METHODS AND MATERIALS: Between January 1998 and June 2002, 367 patients with prostate cancer were treated with I-125 permanent interstitial implantation using a transrectal ultrasound-guided approach. Real-time intraoperative treatment planning which incorporated inverse planning optimization was used. The median follow-up time was 63 months. RESULTS: The median V100 and D90 were 96% and 173 Gy, respectively. In 96% of cases a D90 of >140 Gy was achieved. The median urethral and rectal doses were 100% and 33% of the prescription doses, respectively. The 5-year PSA relapse-free survival outcomes for favorable and intermediate risk patients according to the ASTRO definition were 96% and 89%, respectively. In these patients no dosimetric parameter was identified which influenced the biochemical outcome. Of 38% who developed acute Grade 2 urinary symptoms, 63% had resolution of their symptoms within a median time of 6 months. The incidence of late rectal and urinary Grade 3 or higher toxicities were 1% and 4%, respectively. Seven percent (n = 27) developed late rectal bleeding (Grade 2) and 19% experienced late Grade 2 urinary symptoms. CONCLUSION: Real-time intraoperative planning consistently achieved optimal coverage of the prostate with the prescription dose with concomitant low doses delivered to the urethra and rectum. Biochemical control outcomes were excellent at 5 years and late toxicity was unusual. These data demonstrate that real-time planning methods can consistently and reliably deliver the intended dose distribution to achieve an optimal therapeutic ratio between the target and normal tissue structures.

Brachytherapy↗