PubMed Health⌕ Search

PubMed · 16179209

Method for cortical bone structural analysis from magnetic resonance images.

Abstract

RATIONALE AND OBJECTIVES: Quantitative evaluation of cortical bone architecture as a means to assess bone strength typically is accomplished on the basis of images obtained by means of dual-energy X-ray absorptiometry (DXA) or computed tomography. Magnetic resonance (MR) imaging has potential advantages for this task in that it allows imaging in arbitrary scan planes at high spatial resolution. However, several hurdles have to be overcome to make this approach practical, including resolution of issues related to nonlinear receive coil sensitivity, variations in marrow composition, and the presence of periosteal isointense tissues, which all complicate segmentation. The aim of this study is to develop MR acquisition and analysis methods optimized for the detection of cortical boundaries in such complex geometries as the femoral neck. MATERIALS AND METHODS: Cortical boundary detection is achieved by radially tracing intensity profiles that intersect the periosteal and endosteal boundaries of bone. Profiles subsequently are normalized to the intensity of the marrow signal, processed with morphologic image operators, and binarized. The resulting boundaries are mapped back onto the spatial image, and erroneous boundary points are removed. From the detected cortical boundaries, cortical cross-sectional area and thickness are computed. The method was evaluated on cortical bone specimens and human volunteers on the basis of high-resolution images acquired at a 1.5-Tesla field strength. To assess whether the method is sensitive to detect the expected dependencies of cortical parameters in weight-bearing bone on overall habitus, 10 women aged 46-73 years (mean age, 56 years) underwent the cortical imaging protocol in the proximal femur, and results were compared with DXA bone mineral density parameters of the hip and spine. RESULTS: Reproducibility was approximately 2%. Double oblique images of the femoral neck in the 10 women studied showed that cortical cross-sectional area correlated strongly with height (r = 0.88; p = .0008), whereas cortical diameter versus age approached significance (r = 0.61; p = .06). Measurements in specimens of some cortical parameters indicated resolution dependence. However, note that specimen ranking within each parameter remained constant across all resolutions studied. CONCLUSION: Data suggest the new method to be robust and applicable on standard clinical MR scanners at arbitrary anatomic locations to yield clinically meaningful quantitative results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bryon R Gomberg, Punam K Saha, Felix W Wehrli. 2005. Method for cortical bone structural analysis from magnetic resonance images.. https://doi.org/10.1016/j.acra.2005.06.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗