Error detection in anatomic pathology.

Abstract

OBJECTIVES: To define the magnitude of error occurring in anatomic pathology, to propose a scheme to classify such errors so their influence on clinical outcomes can be evaluated, and to identify quality assurance procedures able to reduce the frequency of errors. DESIGN: (a) Peer-reviewed literature search via PubMed for studies from single institutions and multi-institutional College of American Pathologists Q-Probes studies of anatomic pathology error detection and prevention practices; (b) structured evaluation of defects in surgical pathology reports uncovered in the Department of Pathology and Laboratory Medicine of the Henry Ford Health System in 2001-2003, using a newly validated error taxonomy scheme; and (c) comparative review of anatomic pathology quality assurance procedures proposed to reduce error. RESULTS: Marked differences in both definitions of error and pathology practice make comparison of error detection and prevention procedures among publications from individual institutions impossible. Q-Probes studies further suggest that observer redundancy reduces diagnostic variation and interpretive error, which ranges from 1.2 to 50 errors per 1000 cases; however, it is unclear which forms of such redundancy are the most efficient in uncovering diagnostic error. The proposed error taxonomy tested has shown a very good interobserver agreement of 91.4% (kappa = 0.8780; 95% confidence limit, 0.8416-0.9144), when applied to amended reports, and suggests a distribution of errors among identification, specimen, interpretation, and reporting variables. CONCLUSIONS: Presently, there are no standardized tools for defining error in anatomic pathology, so it cannot be reliably measured nor can its clinical impact be assessed. The authors propose a standardized error classification that would permit measurement of error frequencies, clinical impact of errors, and the effect of error reduction and prevention efforts. In particular, the value of double-reading, case conferences, and consultations (the traditional triad of error control in anatomic pathology) awaits objective assessment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richard J Zarbo, Frederick A Meier, Stephen S Raab. 2005. Error detection in anatomic pathology.. https://doi.org/10.5858/2005-129-1237-ediap

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Does the surface property of a disposable applanation tonometer account for its underestimation of intraocular pressure when compared with the Goldmann tonometer?

BACKGROUND: Disposable tonometers are increasingly being adopted partly because of concerns over the transmission of variant Creutzfeldt-Jakob disease and partly for convenience. Recently, we have found one such tonometer (Tonojet by Luneau Ophthalmologie, France) underestimated the intraocular pressure (IOP). METHODS: We hypothesized that this underestimation was caused by a difference in the surface property of the tonometers. A tensiometer was used to measure the suction force resulting from interfacial tension between a solution of lignocaine and fluorescein and the tonometers. RESULTS: The results showed that the suction force was significantly greater for the Goldmann compared to the Tonojet. CONCLUSIONS: The magnitude of this force was too small to account for the difference in IOP measurements. The Tonojet was less hydrophilic than the Goldmann, and the contact angle of the fluid was therefore greater. For a given tear film, less hydrophilic tonometers will tend to have thicker mires, and this may lead to underestimation of the IOP. When such disposable tonometers are used, it is recommended care should be taken to reject readings from thick mires.

Diagnostic Errors↗