Microscale plasma-initiated patterning (muPIP).

Abstract

A novel technique to create biomolecular micropatterns of varying complexity on several types of polymer substrates is presented. This method uses a patterned PDMS stamp to preferentially expose or protect areas of an underlying polymer substrate from oxygen plasma. Following plasma treatment, the substrate is immersed in a biomolecular ink, whereby molecules preferentially adsorb to either the plasma-exposed or plasma-protected substrate regions, depending on the particular substrate/ink combination. Using this method, polyethylene (PE), polystyrene (PS), poly(methyl methacrylate) (PMMA), poly(dimethylsiloxane) (PDMS), and poly(hydroxybutyrate/hydroxyvalerate) (PHBV) were micropatterned with different aqueous-based biomolecular inks (i.e., goat anti-rabbit immunoglobulin G, poly-l-lysine, and bovine serum albumin (BSA)). Water contact angle measurements performed on substrates after oxygen plasma exposure showed that the hydrophilicity of substrate areas exposed to plasma was significantly greater than that of areas protected from plasma by the PDMS stamp. In addition, scanning electron microscopy results demonstrated that substrate areas exposed to plasma were physically modified (e.g., roughened) compared to adjacent, protected areas. Areas in contact with a patterned PDMS stamp during plasma exposure were found to be physically unaffected by plasma treatment, and exhibited spatial features/dimensions consistent with the corresponding features of the patterned stamp. Last, protein patterns of BSA on the polymer substrates were stable and distinct after 4 weeks of incubation at 37 degrees C.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bryan A Langowski, Kathryn E Uhrich. 2005-11-08. Microscale plasma-initiated patterning (muPIP).. https://doi.org/10.1021/la052222m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Instabilities in nanoporous media.

Rayleigh instabilities in thin polymer films confined within nanoporous alumina membranes were studied. Thin films of poly(methyl methacrylate) (PMMA) were prepared by filling cylindrical nanopores in an anodic aluminum oxide (AAO) membrane with a PMMA solution in chloroform followed by solvent evaporation. When the PMMA nanotubes were annealed above the glass transition temperature (Tg), undulations in the film thickness were observed that were induced by a Rayleigh instability. The amplitude of the undulations increased with time and eventually bridged across the cylindrical nanopore in the AAO membrane, resulting in the formation of polymer nanorods with periodic encapsulated holes. A similar behavior was observed when PMMA films were confined within carbon nanotubes (CNTs). The Rayleigh instabilities in these confined geometries offer a novel means of controlling and fabricating the polymer nanostructures. These compartmentalized nanorods may have potential applications as delivery devices.

Microscopy, Electron, Scanning↗

Efficient and sensitive capacitive readout of nanomechanical resonator arrays.

Here we describe all-electronic broadband motion detection in radio frequency nanomechanical resonators. Our technique relies upon the measurement of small motional capacitance changes using an LC impedance transformation network. We first demonstrate the technique on a single doubly clamped beam resonator with a side gate over a wide range of temperatures from 20 mK to 300 K. We then apply the technique to accomplish multiplexed readout of an array of individually addressable resonators, all embedded in a single high-frequency circuit. This technique may find use in a variety of applications ranging from ultrasensitive mass and force sensing to quantum information processing.

Microscopy, Electron, Scanning↗