The generic advantages of avoiding a large laparotomy incision are now well established. For the patient, a laparoscopic procedure is invariably less painful, and recovery and return to full normal activities is more rapid. There are also significant gains in short-term quality of life measures associated with the laparoscopic approach. For the surgeon, improved visualisation offers the opportunity of more precise and accurate surgery. These advantages are usually offset by longer operating times, the use of complex and expensive equipment, and the possibility of new types of complications and increased risk of standard operative morbidity. The aim of this chapter is to identify areas of general technique in which the risks associated with laparoscopic surgery can be minimised while retaining all the advantages of the approach. This is being achieved partly by improved and simplified instrumentation, partly by refinement in techniques, and partly by an increasing awareness of the potential pitfalls of the approach and by adopting strategies to avoid these problems. The majority of gynaecological procedures are already performed endoscopically and all gynaecologists who operate will need to become proficient in these techniques. This chapter outlines techniques for safe laparoscopic entry and safe bipolar diathermy techniques, and describes how to undertake some of the simpler laparoscopic procedures; the evidence supporting these approaches is also presented. Surgical proficiency in safe laparoscopic entry and laparoscopic tubal surgery should lead to the confidence to then undertake more complex procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ray Garry. 2005-12-20. Laparoscopic surgery.. https://doi.org/10.1016/j.bpobgyn.2005.10.003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prenatal sonographic diagnosis of a rare Cantrell's pentalogy variant with associated open neural tube defect - a case report.

Cantrell's pentalogy is a very rare congenital anomaly. The hallmark of this condition is the presence of ectopia cordis and an abdominal wall defect. Its association with craniorachischisis is even more infrequent with just a few cases reported in the literature. The authors describe a case of a prenatal ultrasound diagnosis of Cantrell's pentalogy with posterior encephalocele and spinal dysraphism associated.

Abdominal Wall↗

Laparoscopically assisted components separation technique for ventral incisional hernia repair.

Reconstruction of the abdominal wall to repair ventral hernias continues to pose a challenge to surgeons due to relatively high rates of recurrence and morbidity. In 1990, Ramirez pioneered a technique of components separation of the abdominal wall for ventral hernia repair. Although an effective hernia repair, the mobilization of skin and subcutaneous tissue endangers the blood supply and predisposes midline skin to necrosis. The goal of this study is to determine whether releasing incisions in the transversus abdominis fascia and posterior rectus sheath provide adequate mobilization of the abdominal wall necessary for ventral hernia repair, thus paving the way for a laparoscopic component separation technique. Ten fresh cadavers were used and one side of the abdomen underwent the conventional Ramirez components separation: midline incision, dissection of skin and subcutaneous tissue off the anterior abdominal wall, and incisions in the external oblique aponeurosis and posterior rectus sheath, while the other side received incisions in the transversus abdominis fascia and the posterior rectus sheath with no undermining of the skin. The amount of fascial translation was measured after each incision. Incising only the external oblique aponeurosis produced greater mobilization of the abdominal wall at the level of the umbilicus (P = 0.02) and anterior superior iliac spine (ASIS, P = 0.029) than releasing only transversus abdominis fascia. More importantly, there was no statistically significant difference in the amount of release produced by the complete internal-release components separation versus the conventional technique. In order to test the feasibility of performing the procedure laparoscopically, one additional cadaver underwent a laparoscopic transversus abdominis fascia release. The procedure was successful and resulted in comparable amounts of fascial release as the other 10 cadavers. From this study, it appears technically feasible to perform a laparoscopic components separation to repair a ventral hernia and the procedure produces the same amount of release as the conventional open component separation technique.

Abdominal Wall↗

Long-lasting bioresorbable poly(lactic acid) (PLA94) mesh: a new approach for soft tissue reinforcement based on an experimental pilot study.

The purpose of this study was to evaluate host response and soft-tissue regeneration after poly(lactic acid) (PLA) mesh implantation in a rat model, in comparison with light-weight polypropylene (PPL) and poly(glycolic acid) (PGA) meshes. Full-thickness abdominal wall defects were created in 45 Wistar rats and reconstructed with 15 PLA(94), 15 PPL and 15 PGA meshes. Animals were killed on days 7, 30 and 90 to evaluate the presence of adhesions and changes in tensile strength of the implants. Histopathology and immunohistochemistry were performed to evaluate the collagen deposition and the inflammatory response. Statistics were done using unpaired Student's t-test, Mann-Whitney rank sum test, Student-Newman-Keuls test and Bonferroni (Dunn) t-test. The inflammatory response induced by the PLA mesh implantation was significantly milder than after PPL mesh. In PLA, vascularity and collagen organization was significantly higher than in PPL and PGA at 30 and 90 days, and collagen composition score was significantly higher than in PPL at 7 and 30 days. In PLA, shrinkage was significantly lower than in PPL and PGA at 7 and 30 days. Elongation at break and tensile strength were comparable between PLA and PPL over the 90-day period. The PLA mesh induces a milder inflammatory response, more orderly collagen deposition than PPL, and preserved comparable tensile strength after 90 days.

Abdominal Wall↗