Ventilation and performance in office work.

Abstract

Outdoor air ventilation rates vary considerably between and within buildings, and may be too low in some spaces. The purpose of this study was to evaluate the potential work performance benefits of increased ventilation. We analyzed the literature relating work performance with ventilation rate and employed statistical analyses with weighting factors to combine the results of different studies. The studies included in the review assessed performance of various tasks in laboratory experiments and measured performance at work in real buildings. Almost all studies found increases in performance with higher ventilation rates. The studies indicated typically a 1-3% improvement in average performance per 10 l/s-person increase in outdoor air ventilation rate. The performance increase per unit increase in ventilation was bigger with ventilation rates below 20 l/s-person and almost negligible with ventilation rates over 45 l/s-person. The performance increase was statistically significant with increased ventilation rates up to 15 l/s-person with 95% CI and up to 17 l/s-person with 90% CI. Practical Implications We have demonstrated a quantitative relationship between work performance and ventilation within a wide range of ventilation rates. The model shows a continuous increase in performance per unit increase in ventilation rate from 6.5 l/s-person to 65 l/s-person. The increase is statistically significant up to 15 l/s-person. This relationship has a high level of uncertainty; however, use of this relationship in ventilation design and feasibility studies may be preferable to the current practice, which ignores the relationship between ventilation and productivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Seppänen, W J Fisk, Q H Lei. 2006. Ventilation and performance in office work.. https://doi.org/10.1111/j.1600-0668.2005.00394.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pilot study of indoor radon in Greek workplaces.

Radon and gamma dose rate measurements have been performed in 561 workplaces in 19 prefectures of Greece. The distribution of radon concentration can be well described by a log-normal distribution. Most of the radon concentrations are between 50 and 200 Bq m(-3) with an arithmetic mean of 123 Bq m(-3). The maximum measured value of radon gas concentration is 695 Bq m(-3). About 10% of the workplaces exceed 200 Bq m(-3). Only a small fraction ( approximately 1%) of workplaces exceed the European Commission action level (400 Bq m(-3)). Despite the relative small fraction of workplaces which exceed the value of 400 Bq m(-3), it is clear from the results of the present work that for certain prefectures, further and more extensive research is needed.

Air Pollution, Indoor↗

Health effects of arsenic, fluorine, and selenium from indoor burning of Chinese coal.

China's economy has developed rapidly in the last two decades, leading to an increase in energy consumption and consequently emissions from energy generation. Coal is a primary energy source in China because of its abundance and will continue to be used in the future. The dominance of coal in energy production is expected to result in increasing levels of exposure to environmental pollution in China. Toxic trace elements emitted during coal combustion are the main sources of indoor air pollution. They are released into the atmosphere mainly in the forms of fine ash and vapors and have the potential to adversely affect human health. Those trace elements, which volatilize during combustion, are hazardous air pollutants (HAPs) and are particularly rich in Chinese coals. Among the HAPs, arsenic (As), fluorine (F), and selenium (Se) have already been identified as pollutants that can induce severe health problems. In this review, the geochemical characteristics of As, F, and Se, including their concentration, distribution, and mode of occurrences in Chinese coal, are documented and discussed. Our investigations have confirmed the current As- and F-induced epidemics in Guizhou (Southwest China) and Se epidemic in Hubei (Northeast China). In this study, diagnostic symptoms of arseniasis, fluorosis, and selenosis are also illustrated.

Air Pollution, Indoor↗