PubMed Health⌕ Search

PubMed · 16446513

Bifurcation intervention: keep it simple.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James B Hermiller. 2006. Bifurcation intervention: keep it simple.. https://pubmed.ncbi.nlm.nih.gov/16446513/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing.

Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected at 1-mm intervals, whereas the electrocardiographically gated approach consists of images in end-diastole. The accuracy in the luminal, P+M, and external elastic membrane (EEM) volumes between 2 pullbacks with the electrocardiographically gated and nongated approaches has not previously been compared. In 15 patients, 19 segments were studied with electrocardiographically gated and nongated IVUS systems. Two identical pullbacks were performed with each system using the same IVUS catheter. Volumes of the lumen, EEM, and P+M obtained using the electrocardiographically gated pullback technique did not differ significantly from the corresponding volumes obtained using the nongated pullback technique (lumen: 109.7 +/- 47.7 vs 109.2 +/- 45.0 mm(3), p = NS; EEM: 242.6 +/- 109.2 vs 235.0 +/- 108.1 mm(3), p = NS; P+M: 134.8 +/- 67.7 vs 129.8 +/- 69.1 mm(3), p = NS). No significant differences were seen in changes between 2 electrocardiographically gated and 2 nongated pullbacks (lumen: 0.37 +/- 1.76 vs -0.23 +/- 2.32 mm(3), p = NS; EEM: 0.25 +/- 3.22 vs -0.94 +/- 4.27 mm(3), p = NS; P+M: -0.18 +/- 3.42 vs -0.74 +/- 3.88 mm(3), p = NS). In conclusion, in moderate atherosclerotic or stented coronary arteries, electrocardiographically gated IVUS acquisition is not superior in accuracy to conventional nongated IVUS acquisition.

Coronary Stenosis↗

EuroSCORE as a predictor of death and myocardial infarction after unprotected left main coronary stenting.

This study aimed to identify the independent predictors of death and myocardial infarction (MI) after unprotected left main coronary artery stenting with bare metal (n = 148) or sirolimus-eluting (n = 176) stents between January 2000 and March 2005. To identify independent predictors of death and nonfatal MI, all available parameters were evaluated. Systemic surgical risk stratification systems such as the EuroSCORE and Parsonnet score were included in the analysis. Clinical information at 9 months was available in 98% of patients (median follow-up 26.3 months). During this period, death/MI occurred in 42 patients (13%). Of the 5 deaths, 4 were related to cardiac and 1 to noncardiac causes. By multivariate Cox regression analysis, a high EuroSCORE (> or =6; hazard ratio 3.4, 95% confidence interval 1.2 to 9.6, p = 0.023), number of stents used (hazard ratio 1.8, 95% confidence interval 1.0 to 3.1, p = 0.042), and treatment with a glycoprotein IIb/IIIa inhibitor (hazard ratio 8.6, 95% confidence interval 2.7 to 27.4, p <0.001) were independent predictors of death/MI. Areas under the receiver-operating characteristic curve of EuroSCORE and number of stents were 0.61 (95% confidence interval 0.52 to 0.70, p = 0.023) and 0.61 (95% confidence interval 0.51 to 0.70, p = 0.028), respectively. In conclusion, high surgical risk estimated by systemic risk stratification of the EuroSCORE appears to be associated with unfavorable outcomes of unprotected left main coronary artery stenting.

Coronary Stenosis↗

Comparison of the efficacy of direct coronary stenting with sirolimus-eluting stents versus stenting with predilation by intravascular ultrasound imaging (from the DIRECT trial).

A direct coronary stenting technique using drug-eluting stents may decrease drug-eluting stent efficacy due to possible damage to the surface coating of the stent. The DIRECT is a multicenter, prospective, nonrandomized trial designed to evaluate the direct stenting strategy for the sirolimus-eluting Bx-Velocity stent compared with the historical control (SIRIUS trial, stenting with predilation). Volumetric and cross-sectional intravascular ultrasound analyses at 8-month follow-up were performed in 115 patients (DIRECT n= 64, control n = 51). Patient and lesion characteristics were comparable between groups. The DIRECT group achieved an equivalent uniform expansion index, defined as minimum stent area/maximum stent area x 100, compared with the control group (65.9 +/- 11.7 vs 63.1 +/- 12.7, p = NS). At 8-month follow-up, vessel, stent, lumen, and neointimal volume index (volume in cubic millimeters/length in millimeters) and percent neointimal volume were similar between the DIRECT and control groups (vessel volume index 13.9 +/- 4.40 vs 15.0 +/- 3.83; stent volume index 6.83 +/- 2.02 vs 6.94 +/- 2.04; lumen volume index 6.71 +/- 2.04 vs 6.81 +/- 2.07; neointimal volume index 0.14 +/- 0.24 vs 0.16 +/- 0.23; percent neointimal volume 3.73 +/- 6.97 vs 3.14 +/- 5.32, p = NS for all). In addition, in-stent neointimal hyperplasia distribution was significantly smaller near the distal stent edge (0.22 vs 0.098 mm(3)/mm, p = 0.01 for an average neointimal volume index within 3 mm from the distal stent edge). In conclusion, direct coronary stenting with the sirolimus-eluting Bx-Velocity stent is equally effective in terms of uniform stent expansion and long-term quantitative intravascular ultrasound results compared with conventional stenting using predilation. This strategy appears to be associated with less neointimal hyperplasia near the distal stent edge.

Coronary Stenosis↗