PubMed Health⌕ Search

PubMed · 16604707

GENII-LIN: a new object-oriented interface for the GENII code.

Abstract

GENII-LIN is a new object-oriented interface for GENII, a well-known analysis tool for the health impact evaluation of accidental or chronic release of radionuclides to the environment. GENII-LIN has been developed under the Linux OS, chosen because it is a stable, reliable and open source. The suite codes that constitute the original GENII simulation kernel have been re-implemented and built, using the G77, the Fortran 77 module of the GCC collection. The code modules and the flow of data among them are at present fully controlled by a management interface written in C++, which is the core of the package. GENII-LIN comes with a new graphical user interface (GUI), built using the QT libraries by Trolltech. Through the wizard-like GUI, the user has full control over the code and can easily handle both the input and the output files.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Sumini, F Teodori, N Cantoro. 2005. GENII-LIN: a new object-oriented interface for the GENII code.. https://doi.org/10.1093/rpd%2Fnci025

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Survey of residential 50 Hz EMF exposure from transformer stations.

In Hungary it is typical that 10/04 kV transformer stations are being installed in multistory residential and office buildings. Magnetic fields (MFs) up to several tens of microT have been measured in apartments close to transformers. The aim of the present study was to provide systematic assessment of MF exposure of residents living above transformer stations. Out of 41 addresses provided by the electricity supplier, current load of 21 transformers and MF in 21 apartments was measured. Spot MFs at 1 m height and time weighted average 24 h MF exposure at bed height was measured. All-day personal MF exposure was measured at waist and HOME exposure was calculated. BED exposure was measured at bed height. Participants kept a time-activity diary. The time-weighted average 24 h MF exposure (3.03 microT) exceeded the usual residential exposure (<0.2 microT). The mean HOME and BED personal exposure above transformers was 0.825 and 1.033 microT, respectively. Our study provides exposure assessment of a cohort with a wider exposure range, compared to power-line epidemiological studies.

Body Burden↗

[Intraoperative radiation exposure in elastic stable intramedullary nailing (ESIN) during the growth period. Observations in 162 long bone shaft fractures].

BACKGROUND: The increase of intraoperative radiation exposure in intramedullary techniques of osteosynthesis is recognised and accepted in adults especially in interlocked nailing. In contrast data about fluoroscopy times in elastic stable intramedullary nailing (ESIN) in children and adolescents are hardly available. MATERIAL AND METHOD: Operation records of 162 surgical procedures (8.6% humerus, 43.8% forearm, 32.7% femur, 14.8% lower leg) of a 3-year period were evaluated retrospectively. The mean age was 6.1 years in femoral shaft fractures, nearly similar in forearm and lower leg fractures (8.7 and 7.9 years, respectively) and 12.4 years in patients with humeral shaft fractures. RESULTS: Mean operation (OP) and fluoroscopy times (FL) were increased in humeral fractures (58.1 min OP, 1.62 min FL), at a medium level in forearm fractures (35.2 min OP, 1.06 min FL) and femoral fractures (42.3 min OP, 1.27 min FL) and shortest in lower leg fractures (29.6 min OP, 0.69 min FL). CONCLUSION: Our results and literature analysis show that optimal technical conditions, especially the use of a pulsed image intensifier and well-trained theatre staff, are able to reduce intraoperative radiation load.

Body Burden↗

Overranging in multisection CT: quantification and relative contribution to dose--comparison of four 16-section CT scanners.

PURPOSE: To quantify the number of overrange rotations and to assess their relative contribution to organ and effective doses at 16-section body computed tomography (CT). MATERIALS AND METHODS: Overranging was quantified for four 16-section scanners by means of free-in-air dose measurements at different scan lengths. Overrange rotations and lengths at a certain section width were derived for all collimations and clinically used pitches by extrapolation. The effect of reconstructed section width on overranging was analyzed separately. Results were applied to clinical protocols for the chest and abdomen. Thyroid and testicular dose and effective dose were established, and relative dose contributions from overranging were calculated. Statistical analysis was performed by using Pearson correlation and paired t tests. P<.05 indicated a significant difference. RESULTS: The number of overrange rotations showed considerable differences between scanners, with a range of 1.99-4.04 at the lowest and 0.93-2.59 at the highest pitch. Number of rotations correlated negatively with pitch, while overrange length correlated positively with collimation and pitch. The effect of section width was variable. In the protocols, overrange length ranged from 3.2 to 5.8 cm for chest and from 3.2 to 5.2 cm for abdominal CT. When the contribution of overranging was not taken into account, significantly lower values for thyroid (P=.012) and testicular (P=.025) doses and effective doses for chest (P=.005) and abdominal (P=.011) CT resulted. CONCLUSION: Overranging is reconstruction-algorithm specific, and its length generally increases with collimation and pitch, while the effect of section width is variable. Overranging may lead to substantial but unnoticed exposure to radiosensitive organs.

Body Burden↗