PubMed Health⌕ Search

PubMed · 16647188

Haemostasis in laparoscopy.

Abstract

OBJECTIVE: Adequate haemostasis is essential for advanced laparoscopic procedures since uncontrolled bleeding may cause significant complications and even required converting to laparotomy to obtain sufficient haemostasis. The aim of this review is to give insight into the most important tools and strategies to achieve sufficient haemostasis during advanced urologic laparoscopy. METHODS AND RESULTS: Lowering the risk of haemorrhage may be achieved primarily by proper case selection, resulting in adequate laparoscopic preparation and dissection technique or the use of local compression by sponge stick to control local bleeding. For early bleeding control, laparoscopic clip appliers, staplers and suturing techniques may be utilised. Various energy sources such as monopolar and bipolar electrocautery, argon beam coagulators, laser or ultrasonic dissectors and topical sealing agents can be used to augment natural haemostasis. CONCLUSIONS: A wide armamentarium for achieving haemostasis during laparoscopy is available. Consequently, laparoscopic surgeons must have detailed knowledge of the physical concepts of each surgical instrument or energy source and of proper use of tissue sealants for obtaining sufficient haemostasis. This knowledge will improve postoperative outcome, increase patient safety and guide laparoscopic techniques to further perspectives.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christoph H Klingler, Mesut Remzi, Michael Marberger, Gunter Janetschek. 2006-02-24. Haemostasis in laparoscopy.. https://doi.org/10.1016/j.eururo.2006.01.058

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗