PubMed Health⌕ Search

PubMed · 16757270

Prometheus system: a technological support in liver failure.

Abstract

The Prometheus system is a plasma filtration treatment coupling adsorption and hemodialysis (FPSA) aimed to blood purification in liver failure. After separation through an albumin-permeable membrane, plasma enters a secondary circuit where protein-bound toxic substances are removed by two adsorbers; p01, a neutral resin, and p02, an anion exchanger. Plasma is then returned to the venous line, where a high-flux hemodialyzer removes water-soluble substances. We used the Prometheus system in 12 patients with acute or acute-on-chronic liver insufficiency: eight cirrhosis, one posttransplant dysfunction, and three secondary liver insult (two cardiogenic shock and one rhabdomyolysis). All patients were severely hyperbilirubinemic, hypercholemic, and hyperammonemic. Twenty-eight sessions each lasting 340 +/- 40 minutes were performed (2.5/patient). The mean total bilirubin decreased from 33.6 +/- 20 to 22.2 +/- 13.6 mg/dL (P < .001); the reduction ratios for cholic acid and ammonia were 48.6% and 51.6%, respectively. The pre- to postsession urea reduction was 57.6% +/- 9.5% and creatinine 42.7% +/- 10%. A significant reduction was observed in the circulating levels of soluble interleukin (IL) 2 receptor (pre: 2687.2 +/- 1434.7; post: 1977.1 +/- 602 Ul/ml; P < .001) and in IL 6 (pre: 56.1 +/- 11.1; post: 35.9 +/- 10.3 pg/mL, P = .05). During treatments the hemodynamics were stable. Two patients received liver transplantations. The secondary liver insult was completely overcome in all three patients. The overall survival at 30 days was 41.6% (5/12 patients). Prometheus, based on FPSA, produced high clearance for protein-bound and water soluble markers, which resulted in high treatment efficacy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Santoro, S Faenza, E Mancini, E Ferramosca, F Grammatico, A Zucchelli, M G Facchini, A D Pinna. 2006. Prometheus system: a technological support in liver failure.. https://doi.org/10.1016/j.transproceed.2006.02.017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗