PubMed Health⌕ Search

PubMed · 16767829

[New CT program simulating kidney displacement during retroperitoneal laparoscopic nephrectomy].

Abstract

A total of 12 patients with malignant localized renal or ureteral neoplasms underwent multi-slice computed tomography. Imaging data were sent to the dedicated workstation to create volume rendering and virtual laparoscopic images of the kidney which was displaced ventrally with retroperitoneal balloon. These findings were compared with video images obtained during retroperitoneal laparoscopic nephrectomy. The kidney displacement simulator depicted all renal arteries (100% sensitivity) and 13 of 14 renal veins (93% sensitivity). Hilar anatomy, including the tumor, major vessels and their relationships were visualized as in the actual laparoscopic views. The desired portions of major vessels as well as the left adrenal and gonadal veins visualized with this system completely corresponded with the actual laparoscopic images during surgery. The kidney displacement simulator is useful to foresee desired portions of major vessels and branched small vessels such as the adrenal or gonadal veins in advance of surgery. It is thus able to guide surgeons and reduce operative risks and possible complications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Tanooka, H Takiuchi, T Sakai, T Nasada, S Hirayama, H Shima, A R Pande, N Nakao. 2006-05-20. [New CT program simulating kidney displacement during retroperitoneal laparoscopic nephrectomy].. https://pubmed.ncbi.nlm.nih.gov/16767829/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗