PubMed Health⌕ Search

PubMed · 16785074

Inhaled steroids do not decrease bone mineral density but increase risk of fractures: data from the GIUMO Study Group.

Abstract

Although the negative effect of systemic steroids on bone is well documented, there is not clear evidence about possible adverse effects of inhaled steroids on bone metabolism and fractures. A cross-sectional study was performed on 105 women suffering from bronchial asthma treated with inhaled steroids and 133 controls. Bone mineral density (BMD) was measured by quantitative ultrasonography (QUS) at the calcaneus and by dual X-ray absorptiometry (DXA), at both the lumbar spine and proximal femur. Patients suffering from bronchial asthma showed no statistically significant changes in BMD as measured by DXA or QUS, compared with controls. A higher prevalence of fractures was found in the group of women with bronchial asthma, with an age-adjusted odds ratio of 2.79 (95% CI: 1.19-6.54). Inhaled steroids do not appear to decrease BMD, but are associated with an increased risk of fracture in women.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Sosa, P Saavedra, C Valero, N Guañabens, X Nogués, J del Pino-Montes, J Mosquera, J Alegre, C Gómez-Alonso, M Muñoz-Torres, M Quesada, R Pérez-Cano, E Jódar, A Torrijos, C Lozano-Tonkin, M Díaz-Curiel, GIUMO Study Group. 2006-04-18. Inhaled steroids do not decrease bone mineral density but increase risk of fractures: data from the GIUMO Study Group.. https://doi.org/10.1016/j.jocd.2005.11.005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗